+44 (0)23 8052 2345
9
MV Heating UK Ltd
Part 2: The Overheat Sensor
Tools:
•
1 x Small Flat-Bladed Screwdriver
Removing the Overheat Sensor:
1)
Remove the cases (
Part 1
).
2)
Unplug the overheat sensor (
2:11
) from the E.C.U. (
2:8
) (two blue wires).
3)
Free the wires from around the E.C.U. hook.
4)
Slide the overheat sensor off the heat exchanger (
2:1
). Using a small flat-
bladed screwdriver as necessary to lever it off.
Refitting the Overheat Sensor:
1)
Replace the overheat sensor on the heat exchanger.
2)
Feed the wires back under the E.C.U. hook to secure them in place.
3)
Plug the overheat sensor back into the E.C.U. paying attention to its
correct orientation.