3.3.5 Replacing Switch Panel Cable Assy
71
3.3 Replacing Cover section
VJ628XE-M-00
3.3.5
Replacing Switch Panel Cable Assy
●
Tools & Jigs & Maintenance part
CAUTION
Before replacing Panel Board Assy, unplug Power cable and leave it for a while.If
operating with Power cable still plugged, Board may be damaged. or operators may
get an electric shock by residual electric charge.
Name
No.
Remarks
Switch Panel Cable Assy
DG-44727 Exploded View Cover
Phillips screwdriver No.2
Generic
products
-
Phillips screwdriverNo.1
-
1
Remove Top Cover.
2
Remove Switch Panel Cable Assy from MAIN
Board.
3
Remove the cable from the claps on the path.
-
4
Remove the screws (2 pieces) retaining SW
Panel Bottom.
A : SW Panel Bottom
B : Tapping screw M3
x
8
S Tight cup
5
Remove SW Panel Bottom.
6
Remove the screws retaining SW Panel
Bottom.
A : Switch Panel Bottom
B : P tight pan M3
x
12
7
Remove Switch Panel Cable Assy from Panel
Board.
A : Switch Panel Cable Assy
B : PANEL Board Assy
8
To reassemble unit, reverse the removal
procedure.
A
B
A
B
A
B