4.3.11 Diagnostic Mode
214
4.3 Working with MUTOH Service Assistance Software
VJ628XE-M-00
(4)
H
ead Temperature Transition Logging
Head temperature transition of the connected printer can be monitored.
[Head temperature transition] graphs vary depending on the number of the print heads.
(4-a)Logging setting
Select Logging setting menu to open the Logging setting window.
㨀㧵㧼
Logging data is sorted by head and saved in plain text format.
No.
Part name
1
Logging details are displayed.
Measuring counter
Starting date
Time
Interval
2
Make settings for logging.
3
Displays the transition of head temperatures.
4
Start logging.
5
Stop logging.
6
Stop logging, and close the logging window.
1
2
3
4
5
6
No.
Part name
1
Set up the destination folder to save logging data.
2
Enter the time for logging.
3
Enter the interval of logging.
Save the setting.
4
1
4
2
3