3.10.2 Replacing Pump Motor Cable
158
3.10 Replacing Maintenance
VJ628XE-M-00
3.10.2
Replacing Pump Motor Cable
●
Tools & Jigs & Maintenance part
㨀㧵㧼
This section describes the procedure to replace the maintenance part, Vacuum FAN
Relay 2 Assy.
In this section, it is referred to as Pump Motor Cable.
Name
No.
Remarks
Vacuum FAN Relay 2 Assy
DF-48995
Exploded View Maintenance
Phillips screwdriver No.2
Generic
products
-
1
Removing R Side Cover.
2
Remove Top Cover.
3
Move Carriage to the left side of Origin.
4
Remove Pump Motor Cable from Waste Fluid
Pump.
A : Connecting point
5
Remove Pump relay cable from the clamps on
the path.
A
6
Remove Pump Motor Cable from MAIN
Board.
7
Replacing Pump Motor Cable.
8
To reassemble unit, reverse the removal
procedure.