3.8.8 Replacing PG Origin Sensor Cable
123
3.8 Replacing Cursor section
VJ628XE-M-00
3.8.8
Replacing PG Origin Sensor Cable
●
Tools & Jigs & Maintenance part
㨀㧵㧼
This section describes the procedure to replace the maintenance part,PG Origin
Sensor Cable.
In this section, it is reffered to as PG Origin Sensor Cable.
Name
No.
Remarks
PG Origin Sensor Cable Assy
DG-43315 Exploded View Cursor
Phillips screwdriver No.2
Generic
products
-
1
Removing R Side Cover.
2
Remove CR Board Cover.
3
Remove PG Origin Sensor Cable from CR
Board.
4
Remove PG Origin Sensor Cable from the
clamps on the path.
J12
5
Remove PG Origin Sensor Cable from PG
Origin Sensor.
A : PG Origin Sensor Cable
6
Replace PG Origin Sensor Cable.
7
To reassemble unit, reverse the removal
procedure.