3.7.3 Replacing PF Encoder Scale
112
3.7 Replacing PF section
VJ628XE-M-00
3.7.3
Replacing PF Encoder Scale
●
Tools & Jigs & Maintenance part
NOTE
This section describes the procedure to replace the maintenance part,PF ENC Scale
Assy.
n this section, it is reffered to as PF Encoder Scale.
Name
No.
Remarks
PF ENC Scale Assy
DF-49028
Exploded View PF Motor
Phillips screwdriver No.2
Generic
products
-
Phillips screwdriverNo.1
-
1
Removing L Side Cover.
2
Remove CR Motor.
3
Remove the screws (2 pieces) retaining PF
Encoder.
A : PF Encoder
B : Tapping screw M2
x
8
4
Remove PF Encoder.
A
B
5
Remove the screws (4 pieces) retaining ENC
Holder.
A : ENC Holder
B : Tapping screw M3
x
8P Tight cup
6
Replace PF Encoder Scale.
NOTE
When handling PF Encoder scale. be
careful with the following.
• Do NOT damage or bend PF Encoder
scale or touch its outer circumference.
• Make sure that slit mounting flange has
NO remaining double-sided tape.
7
To reassemble unit, reverse the removal
procedure.
8
Perform various adjustments.
A
B
B
Make sure that the letters >PET<
can be seen reversely when installed.
Make sure that the letters >POM<
can be seen when installed.