3.6.7 Replacing Lever Sensor
100
3.6 Replacing Y Rail part
VJ628XE-M-00
3.6.7
Replacing Lever Sensor
●
Tools & Jigs & Maintenance part
NOTE
• This section describes the procedure to replace the maintenance part,CR_HP
Sensor, Lever Sensor.In this section, it is reffered to as Lever Sensor.
• Lever Sensor is locker with Thread locker.
Name
No.
Remarks
CR_HP Sensor, Lever Sensor
DF-49471
Exploded View Y Rail Assy
Phillips screwdriver No.2
Generic
products
-
Thread locker
Threebond 1401
1
Removing R Side Cover.
2
Move Carriage to the top of Platen.
3
Remove Lever Sensor Cable from Lever
Sensor.
A : Lever Sensor Cable
B : Lever Sensor
A
B
4
Remove Lever Sensor.
A : Lever Sensor
5
Replace Lever Sensor.
6
To reassemble unit, reverse the removal
procedure.
NOTE
Apply Thread locker to new Lever sensor,
and bond to the bracket firmly.