 S/PDIF COAX IN

These four input interfaces receive an unbalanced, digital audio or empty 
frame signal in coaxial S/PDIF format, electrically based on the specifications 
of the IEC 60958 standard (cinch connector). The input impedance is 75 

.

3

 S/PDIF OPT IN

This input interface receives a digital audio signal in S/PDIF format, optically 
based on the specifications of the IEC 60958 standard (Toshiba Toslink

TM

 

connector, EIAJ standard).
 

4

 AES/EBU OUT

This interface transmits the mix signal in balanced, digital AES/EBU format, 
electrically based on the specifications of the AES 3-1992 standard (R1997). 
The output impedance is 110

 (XLR connector, male).

5

 WORD CLOCK IN / OUT

This input receives a Word Clock or Word Clock x 256 clock signal (known as 
Super Clock for ProTools

TM

 systems) to synchronize the SMART MERGE.

6

 230V (115V)

The mains voltage fuses are located behind this shutter. These must be 
inserted properly according to the voltage of the country in which the 
unit is to be used! Please consult the safety tips, particularly the section 
entitled »Initial Operation« as well as the section »Changing the Mains 
Voltage Fuses« found in the appendix.

7

 SWITCH

This is the main on/off switch for turning on the power supply to the 
unit. The main on/off switch should only be set to its ON position after 
complete and professional wiring of the unit. In particular, ensure that 
the enclosed power cord is properly connected and that the correct 
voltage for the country has been selected (it may be necessary to 
change the mains voltage fuse). Please consult the safety tips for more 
information.

8

 MAINS INPUT

Connect the enclosed power cord here. Before plugging the cable into 
the mains input and wall outlet, ensure that the main on/off switch is 
turned off and that the correct fuse, according to the country-specific 
voltage, is inserted.

7

  

Содержание SMART MERGE

Страница 1: ......

Страница 2: ......

Страница 3: ...bought the product from a MUTEC GmbH specialized dealer or distributor and is not transferable to anyone who may subsequently purchase this product No other person retail dealer distributor etc shall...

Страница 4: ...6 SMART MERGE rear panel 6 INSTALLATION Setting up 8 Wiring the digital audio inputs 8 Wiring the Word Clock interfaces 8 OPERATION Connecting the devices 9 Synchronization 9 The first mix 9 Monitor f...

Страница 5: ...put channels without affecting the mix signal Also every input can be routed separately to the digital master output e g for monitoring on the main speackers or patching digital sources to one input o...

Страница 6: ...on to a reference clock source 4 SINGLE MASTER With this switch the two playback functions of the master output can be switched over 5 MONITOR These five green LEDs indicate which of the inputs is cur...

Страница 7: ...115V The mains voltage fuses are located behind this shutter These must be inserted properly according to the voltage of the country in which the unit is to be used Please consult the safety tips par...

Страница 8: ...This termination must be disabled if the connected Word Clock cable is to be daisy chained to other devices as only the last device in a chain may be terminated Proceed as described in the appendix u...

Страница 9: ...at the same time a usable audio signal present at the first digital audio input the Word Clock signal always has first priority Accordingly the AES EBU master signal is output synchronously to the in...

Страница 10: ...e SINGLE MASTER switch is set to SINGLE the internally generated mix signal is not output constantly through the AES EBU master output as is the case with the MASTER function Just as with the monitor...

Страница 11: ...us the asynchronous output signals of the musical instruments are integrated into the synchronous studio set up Moreover only one input at the mixing desk is used for all instruments 11 Digital Mixing...

Страница 12: ...flat blade screwdriver to open the compartment that houses the fuse holder Carefully pull out the fuse hol der from its socket Turn it by 180 and re insert it into its socket After closing the compart...

Страница 13: ...3 0Vpp 75 output impedance 50 Frequency range Every audio clock rate from 32 0kHz to 108 0kHz and 8 0MHz to 25 0MHz for ProTools fully varispeed compatible SIGNAL PROCESSING DynamicAutoLeveling DAL 3...

Страница 14: ......

Отзывы: