Mutec FS750E Скачать руководство пользователя страница 1

 

Operating Manual 

MSBA00049

 

Date:  

21.03.2019 

Rev.:  

05 

Page  

1 of 14

 

Operating Manual FS750E 

 

 

Mütec Instruments GmbH

 

Tel.: +49 (0) 4185-80 83-0 

E-Mail

[email protected]

 

Bei den Kämpen 26

 

Fax: +49 (0) 4185-80 83-80 

Web:    

www.muetec.de

 

D-21220 Seevetal-Ramelsloh 

 

Dust monitoring  

with analog output  

for the detection of  

filter malfunctions 

Содержание FS750E

Страница 1: ...14 Operating Manual FS750E M tec Instruments GmbH Tel 49 0 4185 80 83 0 E Mail muetec muetec de Bei den K mpen 26 Fax 49 0 4185 80 83 80 Web www muetec de D 21220 Seevetal Ramelsloh Dust monitoring w...

Страница 2: ...Instruments GmbH 2019 All rights reserved This document is copyright protected It supports the user in making reliable and efficient use of the unit Transmission and duplication of this document as we...

Страница 3: ...troduction 6 4 System Design 7 5 General information on construction and operation 7 6 Mounting Instructions 8 6 1 Selection of the mounting position 8 6 2 Sensor Mounting 8 6 3 Transmitter Mounting 9...

Страница 4: ...sical injury may occur if the appropriate precautionary measures are not taken CAUTION without a triangular warning sign means that material damage may occur if the appropriate precautionary measures...

Страница 5: ...extended nor limited by the information contained in the manual The content reflects the technical state of the art regarding printing It is subject to technical modifications in the course of furthe...

Страница 6: ...and the opposite wall The measurement system is based on the triboelectric effect Particles collide permanently with each other or with other materials e g the wall Because of this process the particl...

Страница 7: ...General information on construction and operation Safety instructions If the device can no longer be operated safely it must be put out of operation and secured to prevent unintentional operation The...

Страница 8: ...urement window is performed with an 18 mm drill bit Therefor the previously welded sleeve serves as a drilling template After drilling the borehole on the inner pipe wall needs to be trimmed as much a...

Страница 9: ...tter Mounting Mount the transmitter on a 35 mm DIN rail according to EN 60715 Install the module in a suitable housing to meet the requirements for the protection class The DIN rail transmitter should...

Страница 10: ...pin T2 and the shared ground on pin T4 Shielded connection cables should be used Connect the shield with the ground rail DIN rail As an alternative unshielded connection cables can be used if the cabl...

Страница 11: ...iometer maps the lower measuring range to a current output of 4mA By adjusting the potentiometer to the lower or upper end the current output is increased or decreased by up to 4mA respectively If the...

Страница 12: ...g material Aluminum Material sensor rod V2A V4A option Isolator PPS Protection class IP65 Weight 700g Tightening torque mounting 40Nm Storage temperature 20 C to 70 C not condensing Operating temperat...

Страница 13: ...supply DC voltage 24 VDC 20 to 30 Power consumption max 2 W Power LED green good condition of power supply Housing Material Polyamide Color light grey Protection class IP20 Width x length x height 22...

Страница 14: ...their dimensions The loss of material must not be more than 1mm The transmission of the devices remains reliable and stable over a long period neither regular adjustments nor maintenances are require...