MDS 2112P
Digital Storage Oscilloscope
Quick Guide
Страница 1: ...MDS 2112P Digital Storage Oscilloscope Quick Guide...
Страница 2: ...ervice centre a copy of the customer s proof of purchase is also required This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and...
Страница 3: ...t the Function Inspection 9 How to Implement the Probe Compensation 10 How to Set the Probe Attenuation Coefficient 11 How to Use the Probe Safely 12 How to Implement Self calibration 12 Introduction...
Страница 4: ...be grounded The product must be grounded properly before any connection with its input or output terminal When powered by AC power it is not allowed to measure AC power source directly because the tes...
Страница 5: ...in damage to this product or other property Terms on the product The following terms may appear on this product Danger It indicates an injury or hazard may immediately happen Warning It indicates an i...
Страница 6: ...e AC power when the AC powered oscilloscope is connected to the AC powered PC through the ports Warning To avoid fire or electrical shock when the oscilloscope input signal connected is more than 42V...
Страница 7: ...h which you can set the different options for the current menu The other buttons are function buttons through which you can enter different function menus or obtain a specific function application dir...
Страница 8: ...s 3 AC power input jack 4 Foot stool Adjust the tilt angle of the oscilloscope 5 USB Device port It is used to transfer data when external USB equipment connects to the oscilloscope regarded as slave...
Страница 9: ...n menu Pressing this button is equal to the Save option in the Save menu The waveform configure or the display screen could be saved according to the chosen type in the Save menu 5 Vertical control ar...
Страница 10: ...pture and display the waveform continuously Stop Data acquisition stopped 4 The two blue dotted lines indicates the vertical position of cursor measurement 5 The T pointer indicates the horizontal pos...
Страница 11: ...length 16 The frequency of the trigger signal 17 The readings show current sample rate 18 The readings indicate the corresponding Voltage Division and the Zero Point positions of the channels BW indi...
Страница 12: ...the package With the transportation department or our distributor responsible for this business informed about it a repairing or replacement of the instrument will be arranged by us How to Implement t...
Страница 13: ...hat of the switch in the probe as 10X see How to Set the Probe Attenuation Coefficient on P11 and connect the probe with the CH1 channel If a probe hook tip is used ensure that it keeps in close touch...
Страница 14: ...eft menu corresponding to the probe This setting will be valid all the time before it is changed again Caution The default attenuation coefficient of the probe on the instrument is preset to 10X Make...
Страница 15: ...elf calibration The self calibration application can make the oscilloscope reach the optimum condition rapidly to obtain the most accurate measurement value You can carry out this application program...
Страница 16: ...vity Vertical offset back to 0 shortcut key Turn the Vertical Position knob to change the vertical display position of channel and push the position knob to set the vertical display position back to 0...
Страница 17: ...window The Horizontal Position knob is used to control the triggering displacement of the signal or for other special applications If it is applied to triggering the displacement it can be observed th...
Страница 18: ...utton to display the menu for the settings of the Automatic Measurements At most 8 types of measurements could be displayed on the bottom left of the screen The oscilloscopes provide 30 parameters for...
Страница 19: ...on software on the supplied CD 2 Connection Use a USB data cable to connect the USB Device port in the right panel of the Oscilloscope to the USB port of a PC 3 Install the driver Run the Oscilloscope...
Страница 20: ...n To avoid any damage to the instrument or probe do not exposed it to any sprays liquids or solvents Cleaning Inspect the instrument and probes as often as operating conditions require To clean the in...
Страница 21: ...completely avoiding any electrical short circuit or bodily injury resulting form the moisture Appendix C USB Disk Requirements Support USB disk format USB 2 0 or below FAT16 or FAT32 allocation unit...