21
Red
Indicator
Inflator
Body
Sealing
Ring
FIGURE 18
FIGURE 17
Red
Indicator
Trash
FIGURE 19
7. Squeeze the clear O-ring to
elongate it – until it looks more
like an oval. This will give you
enough room to pull the inflator
body and cylinder out of your
PFD.
8. Gripping the inflator body, pull
it and the cylinder out through
the clear O-ring in the PFD.
(Fig. 18). Discard the used
inflator body and cylinder
(Fig. 19).
PUTTING IN NEW INFLATION
EQUIPMENT
9.
Get the new inflator body and
cylinder from the re-arm kit.
(This is the black circular disc
and the cylinder attached to it).
10. Make sure the indicator on the
inflator body is green.
(If indicator is not green, you
will need a new inflator body
and cylinder before you can
re-arm.)
11. Gripping the inflator body,
insert the cylinder through
the clear O-ring – aligning it
with the screen print on the
covering material (Fig. 20).
(The inflator body will remain
visible.)
12. Line up the clear O-ring on the
grooves of the inflator body so
that O-ring and inflator body
are in even contact all the way
around.
13. Get new (black and yellow)
inflator cap from re-arm kit
and check its face for:
- a green indicator
- a valid expiration date
- If indicator is not green or
the expiry date has already
passed, you will need a
new inflator cap before
you can re-arm.