background image

(1) General

Plug connector only under zero voltage (Insert / Remove).
The compact power supply unit is potted and suitable for harsh environmental conditions.
Only for use in pollution degree 2 environment (Controlled Environment).

(3) Features

[1]

Input terminal:

3-pin 7/8" receptacle male with external threads.
To tighten the mating connector use Murrelektronik 7/8" 1.5 Nm torque wrench set AF 22:
Art. No.: 7000-99104-0000000 with correct 7/8" wrench.

[2]

IO-Link terminal:

4-pin M12 receptacle male with external threads.
To tighten the mating connector use Murrelektronik M12 0.6 Nm torque wrench set AF 13:
Art. No.: 7000-99102-0000000.

[3]

Output terminal:

5-pin 7/8" receptacle female with internal threads.
To tighten the mating connector use Murrelektronik 7/8" 1.5 Nm torque wrench set AF 22:
Art. No.: 7000-99104-0000000 with correct 7/8" wrench.

[4]

DI/DO, LED is yellow / IO-Link, LED is blinking green.

[5]

Input power OK, LED is green.

[6]

Channel is selected when the LED is yellow.

[7]

The channel selector switch. You can turn the output ON or OFF with this switch.

[8]

Channel output is ON / LED is green.

- channel output load is 90% or more from setting current / blinking green LED.
- channel output is OFF / LED is red.
- overcurrent trip / LED is blinking red.

[9]

7-segment display shows the current limit value. When changing the current limit, the dot will

blink.

[10]

Select / set switch.

(4) Functionality

Checking current limit:

Press select switch

[10]

, channel U

S

has yellow LED ON

[6]

and 7-segment display show current

limit, press select switch

[10]

again and channel U

A

has yellow LED ON

[6]

and 7-segment

display show current limit. After checking limits, wait few seconds and channel LED

[6]

will go

OFF.

Adjusting the current limit:

REMARK!

Current setting only when outputs are in OFF mode (automatic).
1. Press select switch

[10]

for 3 seconds.

2. Both channels have yellow LED blinking

[6]

.

3. Select the channel with the channel selector switch

[7]

.

4. 7-segment display

[9]

shows the current value of the current channel and the dot in the display

is blinking.
5. Use select switch

[10]

to set current limit for selected channel (1A -> 2A -> 3A...).

6. After you have set current limit, press channel select switch

[7]

or wait few seconds.

7. To get the channel active, press the switch

[7]

and then channel output LED

[8]

will change

from red to green.

(5) Location

The power supply is cooled by natural convection. Protection degree of the housing is IP67.
Switch-Mode Power Supply for both inside and outside of the cabinet with 7/8’’ input-, 7/8’’ output
connector and M12 IO-Link connector.

(6) Mounting [11]

- front mounting with 6 x M4 screws.
- side mounting with 4 x M4 screws.
Vertical and horizontal mounting is possible. Not for direct sunlight.

(7) Switching on

Check input and output connectors and their connection before switching power on. Current limit
for different outputs U

5

=2 A and U

)

=8 A (factory default).

(8) Loading capacity

The nominal current for one output is 8 A and the total current for both outputs is 10 A. If total
output current goes over 10 A for over 4 seconds, output U

)

will be switched off.

We reserve the right to change this specification.

Product of the Emparro67 series

D-71570 Oppenweiler

Murrelektronik GmbH

Falkenstraße 3

In order to take the best advantage of
the features that this power supply has
to offer and to ensure long term
reliability for your equipment, please
read this manual carefully before
installation and use. It should be
retained for future reference.

Emparro67 10-100-240/24 2xMICO 7/8" IOL

Art. No. 85676

INSTALLATION INSTRUCTIONS

SELECT

<SET>

INPUT OK

IO

-Link

OUT 2 / U

A

OUT 1 / U

S

SELECT

<SET>

OUTPUTS

IO

-Link

DI / DO

1

2

3

11

5

6

7

8

10

4

9

6

7

8

MICO OUTPUTS: 2 x 24 VDC, 240 W, SELV

Emparro67 Hybrid 10-100-240/24 2x MICO 7/8'' IOL

ART. NO. 85676

CAUTION

Read instruction manual before installation and use.

INPUT:

100 - 240 VAC ± 10%

50 - 60 Hz ± 6%

2.7 - 1.2 A

MADE IN CZECH REPUBLIC

DESIGNED IN FINLAND

45012 - 1.00 - 1.00

IP67

100 - 240 VDC - 10% / + 55%

2.7 - 1.1 A

PF 0.95

Surrounding air temperature

-25°C ... +80°C >50°C DERATING

Tc: max. +80°C

Max. 8 A / OUTPUT

Max. 10 A / TOTAL

Operator access area max. +40°C

Tc

INPUT

N / DC-

L / DC+

D-71570 Oppenweiler

Emparr

o

Hybrid

Falkenstraße 3

Murrelektronik GmbH

®

SELECT

<SET>

INPUT OK

IO

-Link

OUT 2 / U

A

OUT 1 / U

S

SELECT

<SET>

OUTPUTS

IO

-Link

DI / DO

IP67

IND.CONT.EQ.

61RM

IND.CONT.EQ.

61RM

N / DC-

L / DC+

+

+

(Us)

(Us)

(U )

A

(U )

A

1

4

3

2

1 24 V

2 DI/DO

3 0 V

4 IO link

(2) Technical specification, Art. No. 85676

V1.1

Nominal voltage

100 - 240 VAC

Input voltage range

90 - 265 VAC

Power distribution systems

TN, TT, IT mains

Nominal frequency

50 - 60 Hz ±6%

Input current, I

nom.

2,7 A

rms

/ 115 VAC - 1,2 A

rms

/ 230 VAC

Inrush current

< 5,9 A / 230 VAC after 1 ms

Efficiency, typ.

91,6% / 115 VAC - 92,8% / 230 VAC

Power factor, typ.

0,99 / 115 VAC - 0,88 / 230 VAC

Output power

240 W

Power losses

< 18,7 W with 230 VAC

No-load power losses

< 3,7 W with 230 VAC

Internal fuse F1:

6,3 A (T)

External fuse max.

20 A in building installations. Circuit

breaker type B or C recommended.

Safety class

1

Output voltage

24 VDC

Output voltage, adjustable via the IO-Link

24 - 28 VDC

Static regulation accuracy

+/- 1%

Dynamic regulation accuracy typ.

0->100%->5%; <2ms:5%, >2ms: 2%

Start-up time

< 0,6 s

Hold up time of the output, typ.

> 20 ms

Output ripple

< 10 mV

rms

Overloading / temperature protection

Yes

Relative humidity

4 - 100%

Maximum surrounding air temperature

-25°C - +80°C (> +50°C derating)

Storage temperature

-40°C - +85°C

Protection class, case, EN 60529

IP67

Dimensions W x H x D; Weight

217 x 110 x 53 mm; 1,9 kg