background image

Introduction

User manual 59719_hdb_en_12

 9 / 65

1.5.2

Trademarks

Trademarks of the following companies and institutions are used in this docu-

mentation:

1.5.3

Specifications

The features of the IO-Link Specification version 1.1.3 are supported as well.

IO-Link

c/o PROFIBUS Nutzerorganisation e.V. (PNO)

Specification

Link

IO-Link

 specification

Version 1.1.2 dated 07/2013

http://www.io-link.com

Содержание 59710

Страница 1: ...ENGLISH MANUAL for devices of the MVP12 series Art No 59710 59718 59719 59810 59818 59819 Murrelektronik GmbH...

Страница 2: ...ns This document applies to the following products Document status Name Art No MVP12 P6 DIO16 8xM12A IOLA12 B0 59719 MVP12 P6 DIO16 8xM12A IOLA12 E0 59819 MVP12 P6 DIO8 DIO8 8xM12A IOLB12 B0 59718 MVP...

Страница 3: ...esignation Code 12 3 2 Module structure 14 3 3 Pin assignment 15 3 3 1 IO Link Class A 15 3 3 2 IO Link Class B 16 4 Technical Data 17 4 1 Art No 59719 17 4 1 1 Electrical data 17 4 1 2 Environmental...

Страница 4: ...32 4 6 2 Environmental characteristics 33 4 6 3 Protection 33 4 6 4 Product reliability 33 4 6 5 Mechanical data 34 4 6 6 Conformity Approvals 34 5 Mounting 35 5 1 Requirements 35 5 2 Dimensions 35 5...

Страница 5: ...7 2 2 4 Mapping of configurations in pin based mapping mode 56 7 3 Diagnostic 57 7 3 1 Vendor specific IO Link events 57 7 4 Process data 58 7 4 1 Port Based Bitmapping 58 7 4 2 Pin Based Bitmapping 6...

Страница 6: ...lossary You can find explanations of the terms abbreviations used at https www murrelektronik com products industries glossary 1 1 Service and support Sales and distribution Our sales employees in the...

Страница 7: ...ling line Disposal The product can be returned to Murrelektronik GmbH free of charge for dis posal The same is true for the original packaging and any batteries or power packs Any units that have been...

Страница 8: ...s CAUTION Low risk danger Failure to observe this warning can lead to mild to moderate injuries NOTICE Possible material damage Failure to observe the warning may cause damage to the device and or the...

Страница 9: ...mpanies and institutions are used in this docu mentation 1 5 3 Specifications The features of the IO Link Specification version 1 1 3 are supported as well IO Link c o PROFIBUS Nutzerorganisation e V...

Страница 10: ...dio interference may occur if the module is used in a domestic or mixed en vironment Follow standards for domestic or mixed environments 2 2 1 Foreseeable misuse Foreseeable misuse The module must not...

Страница 11: ...mm plastic housing 1 x M12 IO Link class A 8 x M12 I O 16 configurable digital inputs outputs IO Link hub in 50 mm plastic housing 1 x M12 IO Link class B 8 x M12 I O 16 configurable digital inputs o...

Страница 12: ...O16 8xM12A IOLA12 E0 MVP12 P6 Product family module size DIO D Digital I Input O Output 8xM12A Number size and coding of the ports A A coding IOLA IOL IO Link A Class A E0 Extended Firmware Features M...

Страница 13: ...size DI D Digital I Input 8xM12A Number size and coding of the ports A A coding IOLA IOL IO Link A Class A B0 Basic Firmware Features MVP12 P6 DI16 8xM12A IOLA12 E0 MVP12 P6 Product family module siz...

Страница 14: ...ons Art No Port designation Explanation 59719 59819 X0 X7 Digital inputs and outputs US XZ1 Module supply IO Link Class A 59718 59818 X0 X3 Digital inputs and outputs UA X4 X7 Digital inputs and outpu...

Страница 15: ...Pin 1 24 V US L Pin 2 n c Pin 3 0 V US L Pin 4 C Q IO Link Pin 5 n c DIO X0 X7 M12 female connec tors Pin 1 24 V US Pin 2 DIO US Pin 3 0 V US Pin 4 DIO US Pin 5 FE IO Link XZ1 M12 male connectors Pin...

Страница 16: ...Z1 M12 male connectors Pin 1 24 V US L Pin 2 24 V UA P24 Pin 3 0 V US L Pin 4 C Q IO Link Pin 5 0 V UA N24 DIO X0 X3 M12 female connec tors Pin 1 24 V UA Pin 2 DIO UA Pin 3 0 V UA Pin 4 DIO UA Pin 5 F...

Страница 17: ...ling 40 mA Galvanic isolation No 0 0 5 I A 1 2 5 1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400 bit s Bus protocol IO Link V1 1 2 compati ble with I...

Страница 18: ...rts 2 6 5 500 Hz const amplitude 1 mm acceleration 15 g Shock test EN 60068 Parts 2 27 50 g 11 ms Electrical safety Degree of protection IP68 Protection class III Degree of pollution 2 Emitted EMC int...

Страница 19: ...ronically Short circuit protection output DO Electronically Protective circuit for input Internal Suppressor diode Product reliability MTTF SN 29500 at 40 C and rated data 57 years Assembly data Weigh...

Страница 20: ...0 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400 bit s Bus protocol IO Link V1 1 2 compati ble with IO Link V1 1 3 IO Link cycle time 1 ms VendorID 0x012F De...

Страница 21: ...ce Radio interference field strength EN 61000 6 4 Emission QP 40 dB V m 30 230 MHzQP 47 dB V m 230 1000 MHz EMC immunity Electrostatic discharge housing EN 61000 4 2 4 kV contact 8 kV air Electromagne...

Страница 22: ...s Assembly data Weight Net 200 g Dimensions L x W x H 126 x 50 x 34 5 mm Conformity Approvals Product standard EN 61131 2 Programmable logic controllers Part 2 Compliant CE 2014 30 EU 2011 65 EU Compl...

Страница 23: ...Derating 4 A Total current UA 50 C see Derating 4 A Power consumption when idling 50 mA Galvanic isolation Yes 0 0 5 I A 1 2 5 1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed...

Страница 24: ...ts 2 6 5 500 Hz const amplitude 1 mm acceleration 15 g Shock test EN 60068 Parts 2 27 50 g 11 ms Electrical safety Degree of protection IP68 Protection class III Degree of pollution 2 Emitted EMC inte...

Страница 25: ...ronically Short circuit protection output DO Electronically Protective circuit for input Internal Suppressor diode Product reliability MTTF SN 29500 at 40 C and rated data 52 years Assembly data Weigh...

Страница 26: ...tal current UA 50 C see Derating 4 A Power consumption when idling 50 mA Galvanic isolation Yes 0 0 5 I A 1 2 5 1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer ra...

Страница 27: ...068 Parts 2 6 5 500 Hz const amplitude 1 mm acceleration 15 g Shock test EN 60068 Parts 2 27 50 g 11 ms Electrical safety Degree of protection IP68 Protection class III Degree of pollution 2 Emitted E...

Страница 28: ...ronically Short circuit protection output DO Electronically Protective circuit for input Internal Suppressor diode Product reliability MTTF SN 29500 at 40 C and rated data 52 years Assembly data Weigh...

Страница 29: ...1 5 2 30 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400 bit s Bus protocol IO Link V1 1 2 compati ble with IO Link V1 1 3 IO Link cycle time 1 ms VendorID 0x...

Страница 30: ...1000 MHz EMC immunity Electrostatic discharge housing EN 61000 4 2 4 kV contact 8 kV air Electromagnetic high frequency fields housing EN 61000 4 3 RF field 10 V m Rapid transient electric disturbance...

Страница 31: ...x W x H 126 x 50 x 34 5 mm Conformity Approvals Product standard EN 61131 2 Programmable logic controllers Part 2 Compliant CE 2014 30 EU 2011 65 EU Compliant UKCA Compliant EMC 2014 30 EU Compliant R...

Страница 32: ...0 0 T C 10 20 10 3 30 20 40 50 60 70 IO Link Communication speed COM3 Transfer rate 230 400 bit s Bus protocol IO Link V1 1 2 compati ble with IO Link V1 1 3 IO Link cycle time 1 ms VendorID 0x012F De...

Страница 33: ...1000 MHz EMC immunity Electrostatic discharge housing EN 61000 4 2 4 kV contact 8 kV air Electromagnetic high frequency fields housing EN 61000 4 3 RF field 10 V m Rapid transient electric disturbance...

Страница 34: ...x W x H 126 x 50 x 34 5 mm Conformity Approvals Product standard EN 61131 2 Programmable logic controllers Part 2 Compliant CE 2014 30 EU 2011 65 EU Compliant UKCA Compliant EMC 2014 30 EU Compliant R...

Страница 35: ...unting surface to avoid mechanical tension Provide suitable grounding Suitable installation site in terms of vibration and shock load temperature and humidity see chap 4 Technical Data Protected to av...

Страница 36: ...ect installation The fastening screws and tightening torques depend on the surface of the in stallation site Use fastening screws that are suitable for the mounting surface structure Carefully tighten...

Страница 37: ...M4 bolt 3 Slightly tighten the second M4 bolt 4 Slightly tighten the third M4 bolt 5 Carefully tighten all three M4 bolts see tightening torque Fig 4 3 Fasten ing 6 Grounding the module Fasten the ri...

Страница 38: ...uring connection work According to IEC 60364 Protection against electric shock CAUTION Hot surface Burnings and line damage caused by touching the devices Wear thermally suitable protective gloves Onl...

Страница 39: ...only guaranteed if all connections are sealed with plug connectors screw plugs or sealing caps Seal unused male and female connectors Connecting cables Fig 6 1 Connecting cables PRODUCTS AND ACCESSOR...

Страница 40: ...S and IO Link The device has a combined LED for the IO Link status and the status of the US sensor supply The IO Link status is mapped by the green LED chip and the US status by the red LED chip This...

Страница 41: ...O Link in IDLE status Firmware update completed success fully Green Flashing 1 Hz IO Link in status PREOPERATE OP ERATE update is not yet performed Red Permanently on Update failed Green Red Flashing...

Страница 42: ...per formed 0 ISDU index DPP index Object name Access Length in bytes Meaning default value Identification DIO8 Art No 59719 DIO8 Art No 59819 0x0000 0x00 MasterCommand W 1 0x01 MasterCycleTime R W 1 0...

Страница 43: ...t during production 0x0016 HardwareRevision R 64 e g 01 00 0x0017 FirmwareRevision R 64 e g V 1 00 00 0x0018 ApplicationSpe cificTag R 16 32 User specific designation e g System 3 Port 4 0x0019 Functi...

Страница 44: ...ariable 0x000D ProfileCharacteristic R variable 0x000E PDInputDescriptor R variable 0x000F PDOutputDescriptor R variable 0x0010 VendorName R 64 Murrelektronik GmbH 0x0011 VendorText R 64 www murrelekt...

Страница 45: ...pecification 3 Functional Check 4 Failure 5 255 Reserved 0x0025 DetailedDeviceSta tus R variable 6 x octet 1 EventQualifier octet 2 3 EventCode 0x0028 ProcessDataInput R PD length 0x0029 ProcessDataOu...

Страница 46: ...Index R variable 0x000D ProfileCharacteristic R variable 0x000E PDInputDescriptor R variable 0x000F PDOutputDescriptor R variable 0x0010 VendorName R 64 Murrelektronik GmbH 0x0011 VendorText R 64 www...

Страница 47: ...pecification 3 Functional Check 4 Failure 5 255 Reserved 0x0025 DetailedDeviceSta tus R variable 6 x octet 1 EventQualifier octet 2 3 EventCode 0x0028 ProcessDataInput R PD length 0x0029 ProcessDataOu...

Страница 48: ...16 X7 Pin 2 0x0060 Identification Identification ID R W 1 Identification number for module identification The value is shown inside the input process data 0x0000 0x0061 Identification User Defined Se...

Страница 49: ...ubindex 2 X0 Pin 2 Subindex 15 X7 Pin 4 Subindex 16 X7 Pin 2 Setting per channel subindex 0 0 ms OFF 1 10 ms 2 20 ms 3 30 ms 255 reserved 0 0x0082 Inputs Input Debounce Filter Time R W 1 Setting of th...

Страница 50: ...h individual output channel in the event of a loss of communication with the master Subindex 1 X0 Pin 4 Subindex 2 X0 Pin 2 Subindex 15 X7 Pin 4 Subindex 16 X7 Pin 2 Setting per channel subindex 0 log...

Страница 51: ...Subindex 15 X7 Pin 4 Subindex 16 X7 Pin 2 0x0060 Identification Identification ID R W 1 Identification number for module identification The value is shown inside the input process data 0x0000 0x0061 I...

Страница 52: ...bindex 2 X0 Pin 2 Subindex 15 X7 Pin 4 Subindex 16 X7 Pin 2 Setting per channel subindex 0 0 ms OFF 1 10 ms 2 20 ms 3 30 ms 255 reserved 0 0x0082 Inputs Input Debounce Filter Time R W 16 Setting of th...

Страница 53: ...individual output channel in the event of a loss of communication with the master Subindex 1 X0 Pin 4 Subindex 2 X0 Pin 2 Subindex 15 X7 Pin 4 Subindex 16 X7 Pin 2 Setting per channel subindex 0 logi...

Страница 54: ...e transmission to Master Subindex 2 US Diagnosis low voltage Subindex 3 US Diagnosis Over voltage Subindex 4 US LED status Subindex 5 UA Diagnosis not connected Subindex 6 UA Diagnosis low voltage Sub...

Страница 55: ...pulses in steps of 10 ms Subindex 1 X0 Pin 4 Subindex 2 X0 Pin 2 Subindex 15 X7 Pin 4 Subindex 16 X7 Pin 2 Setting per channel subindex 0 0 ms OFF 1 10 ms 2 20 ms 3 30 ms 255 reserved 0 0x0082 Inputs...

Страница 56: ...of channel A channel B has to be set Channel A Channel B Pin4_X0 Pin4_X0 Pin4_X1 Pin2_X0 Pin4_X2 Pin4_X1 Pin4_X3 Pin2_X1 Pin4_X4 Pin4_X2 Pin4_X5 Pin2_X2 Pin4_X6 Pin4_X3 Pin4_X7 Pin2_X3 Pin2_X0 Pin4_X4...

Страница 57: ...cuit Port 1 Pin 4 0x8CA3 Error DIO pin current overload shortcircuit Port 1 Pin 2 0x8CA4 Error DIO pin current overload shortcircuit Port 2 Pin 4 0x8CA5 Error DIO pin current overload shortcircuit Por...

Страница 58: ...Pin4_X6 5 Pin2_X6 6 Pin4_X7 7 Pin2_X7 Byte 2 Diagnostic Bit Description 0 Error Warning at power supply too low or high 1 Error Warning because of temperature rating threshold can be defined inside o...

Страница 59: ...e identification bits e g for tool change applications 0 not used 1 255 ID value is read out from object Byte 0 Outputs X0 X3 Bit Contact 0 Pin4_X0 1 Pin2_X0 2 Pin4_X1 3 Pin2_X1 4 Pin4_X2 5 Pin2_X2 6...

Страница 60: ...er supply too low or high 1 Error Warning because of temperature rating threshold can be defined inside object 2 Error Warning at Input Output short circuit or overload 3 DIA at channel X 0 channel 1...

Страница 61: ...utput Process Data Byte 0 Outputs X0 X3 Bit Contact 0 Pin4_X0 1 Pin2_X0 2 Pin4_X1 3 Pin2_X1 4 Pin4_X2 5 Pin2_X2 6 Pin4_X3 7 Pin2_X3 Byte 1 Outputs X4 X7 Bit Contact 0 Pin4_X4 1 Pin2_X4 2 Pin4_X5 3 Pin...

Страница 62: ...manual 59719_hdb_en_12 62 65 8 Maintenance and cleaning NOTE Replace defective or damaged devices Device cleaning Use only oil free compressed air or spirit Only use lint free materials e g leather c...

Страница 63: ...our catalog or in our Murrelektronik online shop https shop murrelektronik com Description Art No Screw Plug M12 Metal 996049 Plastic M12 screw plug VE10 58627 Metal addressing lid 55317 Grounding str...

Страница 64: ...is technical documenta tion to create their own technical documentation For this purpose the docu mentation produced by Murrelektronik GmbH may be changed in parts or amended or copied and transferred...

Страница 65: ...NY 49 7191 47 0 49 7191 47 491 000 info murrelektronik com www murrelektronik com The information in the manual has been compiled with utmost care Liability for the correctness completeness and topica...

Отзывы: