Section 80
00-02-0829
2018-02-26
-
27 -
POR Command Value
Commanded PWM %
Actual PWM %
11010
-37.5
-37.5
11001
-43.75
-43.75
11000
-50
-50
10111
-56.25
-56.25
10110
-62.5
-62.5
10101
-68.75
-68.75
10100
-75
-75
10011
-81.25
-81.25
10010
-87.5
-87.5
10001
-93.75
-93.75
10000
-100
-100
4.3.1.7 POR Enable
POR enables the above power on reset functionality for the individual output.
1 Disabled
0 Enabled
Data Length:
1 bit
Resolution:
2 states / 1 bit
0 offset
Data Range:
0 to 1
Operational Range: same as data range
Type:
Status (command)
PGN:
4.3.1.8 Command Type
Command type determines if the loss of CAN feature is enabled or disabled.
0 Enabled
1 Disabled
Data Length:
1 bit
Resolution:
2 states / 1 bit
0 offset
Data Range:
0 to 1
Operational Range: same as data range
Type:
Status (command)
PGN:
Содержание Xpansion IX3212
Страница 1: ...00 02 0829 2018 02 26 Section 80 Intelligent Xpansion Series IX3212 PDM Reference Manual ...
Страница 10: ...Section 80 00 02 0829 2018 02 26 8 2 2 Dimensions IX3212 PDM Dimensions ...
Страница 61: ...NOTES ...
Страница 62: ......