background image

MP-8802N page 1 of 2

Magnetic Pickup Installation Instructions 

Models: MP3298, MP7905, and MP7906

MP-8802N

Revised 03-02

Section 20

(00-02-0181)

Description

A magnetic pickup is an AC generator. It is normally installed into the fly-
wheel housing of an internal combustion engine, so that the starter ring
gear acts upon it to generate a voltage pulse each time a gear tooth passes
the end of the sensor. 

Specifications

Housing Material: 

MP3298

:

Type 300 Stainless Steel.

Locknut:

Type 300 Stainless Steel.

MP7905 and MP7906

:

Type 6061 Aluminum/Anodize Class 1.

Locknut:

Steel Nickel Plated.

Output Leads (all models):

Two insulated leads, 20AWG, STR/TEF 

insulated per MIL-W-16878D Type E, 1 White and 1 Black.

Output Voltage (all models): 

200 V.P.P. TYP. (tested at 1000 I.P.S. 

20 Pitch gear, 0.005 Gap., and 100K OHM Load).

Coil Resistance:

MP3298

:

975 Ohms TYP.

MP7905 and MP7906

:

2500 Ohms TYP.

Potting (all models): 

Internal portion of pickup is filled with epoxy resin, 

making the magnetic pickup oil and moist resistant.

Temperature (all models): 

-65° to +225°F (-54 ° to 107°C).

Coil Induct.: 

MP3298

:

800 mH max, @ 1K Hz.

MP3298

:

400 mH TYP. @ 1K Hz.

Pickup     Part

Total

Threaded

Thread

Model    Number Length

Length

Size

MP3298   

20700162

3 in. (76 mm)

3 in. (76 mm)

5/8-18 UNF

MP7906   

20700161

3 in. (76 mm)

3 in. (76 mm)

3/4-16 UNF

MP7905

20700160

4-1/2 in. (114 mm) 4-1/2 in. (114 mm) 3/4-16 UNF

Gap Chart

Please read the following information before installing

.  

A visual inspection of this product for damage 

during shipping is recommended before mounting. These instructions are intended for MP3298, MP7905, and MP7906 models.

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

THREAD

SIZE

5/8-18 UNF

3/4-16 UNF

1/4

1/2

3/4

1

GAP

.013 in. 

.028 in.

.035 in.

.055 in.

(0.33 mm)

(0.71 mm)

(0.88 mm)

(1.39 mm)

.015 in.

.030 in.

.045 in.

.062 in.

(0.38 mm)

(0.76 mm)

(1.14 mm)

(1.57 mm)

TURN

Typical Installation

Magnetic Pickup Installation 

(see diagram below) 

Drill and tap a hole in the flywheel housing (See Specifications for 
model and thread size).  

IMPORTANT:

Drilling too deep may damage

ring gear teeth. Blow chips with air hose when drilling and tapping hole.

Gap Adjustment

Insert magnetic pickup and turn until it stops at
the face of the gear. Back-off the gear by turn-
ing the pickup counter-clockwise 1/4, 1/2, or
3/4 turn (drawing right) .
See Gap Chart below to determine gap distance
based on the turn. Check gap clearance by
rotating the gear completely around. 

NOTE:

Magnetic pickup gap should be adjusted so

that the minimum voltage required is attained at the engine’s lowest
RPM. The voltage will increase as the speed increases.

If erratic readings occur, remove magnetic pickup and check the 
magnetic tip for metal chips.

1/4

 

1/2

 

3/4

AC

Meter

LOAD

Tach
Speed
Switch

AC Meter

Reading must 
be taken at load. 

After adjusting,
set lock-nut.

Drill and tap casing
(see thread sizes in 
Specifications).

Casing

Gear (must be made
of magnetic material).

NOTE: Clean gear casing
and magnetic sensor 
of metal chips or filings.

Gap

(see Gap Chart)

Always use a two-conductor shielded cable. Ground the
shield to a metal frame ground at the engine end only.

Never run these wires
next to spark plug wires
or in wire loom with other
wires carrying inductive
loads or alternating current.

GENERAL INFORMATION