CLEANING & MAINTENANCE GUIDE:
1.
Motors have lifetime lubrication and do not require scheduled maintenance.
2.
Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it
will cycle on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air
hose or brush the condenser fins and cabinet ventilation louvers. In environments where dirt and dust is
more prevalent, clean more frequently.
3.
Periodically remove fountain top and clean out in-line strainer.
4.
Periodically remove access panel of cooler and clean out inline “Y’’ strainer
For Powder coated units:
Units should be cleaned using a mild soap solution with a sponge or cotton cloth.
Wipe down surfaces then rinse with clean water.
For Stainless steel units:
3. Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/polish is maintained,
stainless steel surfaces will retain their new, clean, polished appearance indefinitely.
1. To Remove water spots or rust spots, stainless steel cleaner/polish on a cloth is recommended.
2. If there are stubborn spots or if you wish to treat a scratch, synthetic abrasive general purpose pads such as
scotch brite are recommended.
CARTRIDGE VALVE PARTS BREAKDOWN
3
2
1
5
4
Note: Use the Universal Maintenance Tool to perform the following:
2. Clean Strainer as needed using clean water.
CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE
1. Strainer Plug must be removed before Cartridge replacement and Strainer maintenance (no need to turn the
water off at the Angle Stop). Some residual water will drainduring Plug removal.
3. Cartridge Replacement - insert diamond end of the Universal Tool into Pushbutton, rotate 90 degrees and pull
firmly to remove the Button. Remove Cartridge Retaining Nut . Remove and replace Cartridge. When replacing
Cartridge, be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body.
—
NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.
-Button Removal
Universal Maintenance Tool
-Cartridge Retaining Nut
-Strainer Plug
-Removal of P.E. Tubing from
Push-in Fittings
6
ITEM #
PART NUMBER DESCRIPTION
1
7003-095-000
Valve Body Sub Assembly
2
7000-060-000
Valve Cartridge
3
7000-052-000
Retaining Nut
4
7003-864-000
Strainer, Auto Stop
5
7003-097-001
Strainer Cap
6
7003-194-199
Maintenance Tool