background image

 

A151-VR-BF4

Page 11 of 19

New: 

10/28/2020

7021-021-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Description

Illuminated LCD display, counts bottles, and has a filter replacement alert function

Bottle Counting Function

The software applies a flow volume of approximately 16.9 fl oz (volume in standard size plastic water 
bottle) to each bottle counted. If the flow volume is less than 16.9 fl oz there will be no count but the 
volume will accumulate, so that part way through the next cycle the total bottle count will change.

See the following page for models with -BCD Bottle Counter Display (A151-BF4-BCD)

OPTIONAL -BCD BOTTLE COUNTER DISPLAY 

BOTTLE COUNTER ADJUSTING & RESETTING INSTRUCTIONS:

NOTE: Bottle Counter Has Multiple Functions

Reset/ Mode Button
• Counts refilled bottles, otherwise purchased
• Adjustable for Units with and without filters
• “REPLACEMENT FILTER” alert function
• Alert reset, when filter is replaced

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

ILLUMINATED LCD DISPLAY

Содержание A151-VR-BF4 Series

Страница 1: ...lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fou...

Страница 2: ...his requirement NOTICE ROUGHING IN AND DIMENSIONAL DRAWING A151400S VR BF4 Wall Mounted Drinking Fountain NOTES Dimensions shown for Adult ADA compliant installation For Child ADA compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes A151 VR BF4 P...

Страница 3: ... are no mounting changes to be made for SO models NOTE DIMENSION INDICTED WITH IS FOR 33 DRINKING FOUNTAIN DISCHARGE HEIGHT IF DISCHARGE HEIGHT DIFFERS ADJUST ACCORDINGLY 1 1 4 O D DRINKING FOUNTAIN WASTE OUTLET 3 8 NCT DRINKING FOUNTAIN SUPPLY INLET ALTERNATE 3 8 NCT BOTTLE FILLER SUPPLY INLETS ALTERNATE 1 1 4 O D BOTTLE FILLER WASTE OUTLET ELECTRICAL SERVICE ROUGH 1 2 3 4 5 CONTEMPORARY WATER CO...

Страница 4: ...KAGING PREVENTING DAMAGE C INSTALLATION INSTRUCTIONS B A PROVIDE 19 1 8 WIDE x 31 1 8 TALL WALL OPENING AT APPROPRIATE HEIGHT PROVIDE STRUCTURAL SUPPORT AROUND INSIDE OF THE OPENING FOR FRAME ANCHORING CAREFULLY REMOVE BI LEVEL MOUNTING FRAME 1 CENTER BOTH FRAMES WITHIN WALL OPENING WITH SIDE UP AGAINST FINISHED WALL FACE SECURE TO WALL THROUGH THE SIDES TOP AND BOTTOM USING HARDWARE 2 BY OTHERS E...

Страница 5: ...sure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices shall be installed as close as possible to the quick closing valve 5 Receptacle s must be wired to a GFCI protected circuit Fixture must be earth grounded per NEC National Electrical Code 5 All burrs must be removed from outside of cut tubes befo...

Страница 6: ...st activating drinking fountain to prevent excessive splashing Depress front push pad until steady water stream is achieved NOTE BEFORE PERFORMING STEP 4 REFER TO ELECTRICAL INSTALLATION 2 Loosen slip nuts to orientate P trap to desired direction then tighten slip nuts and make up 1 1 4 O D waste connection 3 If water flow requires adjustment insert a slotted narrow blade screwdriver in the hole c...

Страница 7: ...ATER TUBING CONNECTIONS NOTE Insulation on all water tubes not shown all PE water tubes are insulated CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS Multi Line Y Strainer Assembly 9 12VDC Solenoid Valve Solenoid Valve Inlet Fitting Fill Spout Solenoid Valve Outlet Elbow w Flow Control Sensor 3 8 O D Copper Inlet PE Tubing PE Tubing...

Страница 8: ... C E I N S T R U C T I O N S DRINKING FOUNTAINS FILTER MOUNTING DETAIL BACKVIEW Out In Mount Filter Bracket to Corner of Mounting Frame 1 2 3 4 5 In Out Connect 1 4 Tubings to Drinking Fountains and Bottle Filler Valve 7 6 WATER TUBING DIAGRAM ITEM PART NUMBER DESCRIPTION 1 0250 006 000 10 x 5 8 Phillips Truss Head Screw 2 7014 035 199 Water Filter Bracket 3 0124 031 000 8 x 3 8 Hex Washer Head Sc...

Страница 9: ...h the filter assembly secured on the unit hold the cap firmly turn the replaceable cartridge filter counterclockwise to remove 3 Remove and replace the cartridge turning clockwise to secure OPTIONAL WF1 WATER FILTER INSTALLATION 4 Turn inlet 1 4 turn knob 1 4 turn counterclockwise to open and test for leaks and proper operation before remounting panel assembly to fixture CONTEMPORARY WATER COOLERS...

Страница 10: ...former provided into GFCI protected electrical service used by the semi recessed bottle filler Plug in transformer to power supply and connect to red sensor wire ELECTRICAL INSTALLATION NOTE Plug in power is a standard feature 9 12VDC Solenoid Valve Plug In Transformer Sensor Red Wire Blue Wire Junction Box Provided CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U...

Страница 11: ... less than 16 9 fl oz there will be no count but the volume will accumulate so that part way through the next cycle the total bottle count will change See the following page for models with BCD Bottle Counter Display A151 BF4 BCD OPTIONAL BCD BOTTLE COUNTER DISPLAY BOTTLE COUNTER ADJUSTING RESETTING INSTRUCTIONS NOTE Bottle Counter Has Multiple Functions Reset Mode Button Counts refilled bottles o...

Страница 12: ...it has a filter or does not have a filter The reset button will also take away the REPLACE FILTER alert once the filter has been replaced OPTIONAL BCD BOTTLE COUNTER DISPLAY Systems With or Without Filter Depress the Reset Mode selection button for 6 Seconds the number of seconds will count up on the display At the end of the 6 seconds FLTR YES or FLTR NO WILL APPEAR on the display FLTR YES means ...

Страница 13: ... POWER SUPPLY CONNECTION BLACK CABLES SENSOR CONNECTION BLACK RED CABLES SENSOR CONNECTION TRANSFORMER SOLENOID VALVE BOTTLE COUNT DISPLAY SENSOR OPTIONAL BCD BOTTLE COUNTER DISPLAY BOTTLE FILLER BOTTLE COUNTER CONNECTIONS See the following page for models with BCD Bottle Counter Display A151 VR BF4 BCD CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S ...

Страница 14: ... THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be...

Страница 15: ...ed 1 ADJUSTMENTS b Cold Water Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clockwise to make colder and counterclockwise to make warmer c Check for twists or kinks in outlet tubing 4 IF LIGHT WITHIN SENSOR DOES NOT FLASH ONCE WHEN USER IS WITHIN RANGE 3 WATER DRIPS OR WILL NOT SHUT OFF f Check flow adjustment See start up note 3 h No power to transformer...

Страница 16: ...nless steel surfaces will retain their new clean polished appearance indefinitely 1 To Remove water spots or rust spots stainless steel cleaner polish on a cloth is recommended 2 If there are stubborn spots or if you wish to treat a scratch synthetic abrasive general purpose pads such as scotch brite are recommended CARTRIDGE VALVE PARTS BREAKDOWN 3 2 1 5 4 Note Use the Universal Maintenance Tool ...

Страница 17: ...cheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x 1 Hex Flat Head Screw 13 0124 055 000 8 x 3 4 Phillips Round Head Screw 6A 7000 012 001 Stainless Steel Bubbler Assembly 14 7003 198 199 Mounting Sleeve 6B 7000 099 002 Flexible Gray Bubbler Assembly 15 7003 095 001 Valve Body Sub Assembly 7 1895 123 000 1 4 x 3 8 OD Tube Union Pu...

Страница 18: ...151 VR BF4 Page 18 of 19 New 10 28 2020 7021 021 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 11 14 13 19 17 12 21 28A 38 22 23 24 25 26 37 36 33 29 30 31 32 34 33 10 8 7 16 15 18 6 2...

Страница 19: ...lips Truss Head Screw 16 7013 232 199 Y Strainer Bracket Clamp 17 7013 220 001 Y Strainer Assembly BF4 18 0112 021 000 10 32 x 1 2 S S Hex Screw 19 7013 221 199 Bracket Y Strainer Mount 20 7000 245 000 Back Panel Spacer 21 7014 215 199 Upper Trim Panel 4 Finish BF4 22 Drinking Fountain See Drinking Fountain Repair Parts for components 23 0116 013 000 10 32 x 3 4 Phillips Round Head Screw 24 7013 1...

Отзывы: