![Munters Rotem Trio 20 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/munters/rotem-trio-20/rotem-trio-20_user-and-installation-manual_1856897030.webp)
© Munters AB, 2020
30
3.4.6.5
Ammonia Sensor Wiring
Figure 21: Ammonia Sensor Wiring
No. Function
1
COM port (Green wire)
2
S port (Brown wire)
3
White wire
4
Phase (Brown wire)
5
Neutral (Blue wire)
6
18-30VDC (Red wire)
7
COM (Black wire)
8
20.3 kohm resistor (Note: The resistor comes supplied with the sensor but must be installed on-
site.)
9
Quick connector
Figure 22: Ammonia Wiring Schematic
•
Connect an ammonia sensor to a:
o
S port. In the corresponding dipswitch, raise dipswitch 3 (analog input).
o
COM port.
Содержание Rotem Trio 20
Страница 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Страница 44: ... Munters AB 2020 44 ...
Страница 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Страница 110: ... Munters AB 2020 110 4 Click the fan in the upper right Both fans turn blue 5 Define fans as required ...
Страница 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Страница 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Страница 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Страница 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Страница 170: ... Munters AB 2020 170 Card Description Munters Ordering Number TUBES AND FILTERS FOR RPS NO RPS CARD 999 99 00503 ...
Страница 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Страница 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Страница 202: ... Munters AB 2020 202 example only ...