background image

 

Operation Manual MK200 

 

2. Installation 

 

Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer 
is not responsible if an incorrect installation and use causes injuries and damages. Always keep the 
instructions with the appliance for future reference. 
 

 

WARNING! 

Flammable material. This appliance contains R290/Propane a flammable refrigerant. 

 
Do not use mechanical devices or other means to accelerate the defrosting process, other than those 
recommended by the manufacturer.  
The appliance shall not be stored in a room with continously operating ignition sources (for example; 
open flames, an operating gas appliance or an operation electric heater). Do not pierce or burn.  
Be aware that refrigerants may not contain an odour. 
Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only 
use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects.  
If the supply cord is damaged, it must be replaced by the manufacturer, Munters Service or similarly 
qualified persons in order to avoid a hazard. 
 

 

CAUTION! 

Only a qualified person must install this appliance. Remove all the packaging. Do not install or use a damaged 
appliance. 
 

The appliance shall be installed, operated and stored in a room with a floor area larger than 4m². Obey the 
installation instruction supplied with the appliance.  
Always be careful when you move the appliance because it is heavy. Always wear safety gloves.  
Make sure the air can circulate around the appliance.  
Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow 
back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not 
install the appliance where there is direct sunlight. 
 

2.1 Electrical connection 

 

WARNING! 

Risk of fire and electrical shock. The appliance must be connected to a grounded outlet. 

 
Make sure that the electrical information on the rating plate agrees with the power supply. If not, contact 
an electrician.  
Always use a correctly installed shockproof socket and make sure that the power supply is sufficiently 
fused. Do not use multi-plug adapters and extension cables.  
Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable).  
Contact the Munters Service or an electrician to change the electrical components.  
The mains cable must stay below the level of the mains plug. Connect the mains plug to the mains socket 
only at the end of the installation. Make sure that there is access to the mains plug after the installation.  
Do not pull the mains cable to disconnect the appliance. Always pull at the mains plug. 
 

 

Содержание MK200

Страница 1: ...Operation Manual Dehumidifier MK200 Valid from 15 10 2018 ...

Страница 2: ...Operation of dehumidifier 5 3 2 Automatic shut off and float switch 6 3 3 Drainage of water 6 3 3 1 Using the hose 6 3 3 2 Without hose directly to a drain outlet 6 3 4 Humidity Control 7 3 5 Air filter 7 3 6 Automatic defrosting 7 3 7 Fan 7 4 Operation principle 8 4 1 Maintenance and cleaning 8 4 2 Trouble shooting 9 5 Technical data ansd warranty 10 5 1 Technical data 10 5 2 Warranty 10 6 Wiring...

Страница 3: ...he full warranty period is serviced and maintained by a qualified Munters engineer or Munters approved engineer Access to specific and calibrated test equipment is necessary The service and maintenance must be documented for the warranty to be valid Always contact Munters for service or repair Operating faults can occur if the unit is maintained insufficiently or incorrectly 1 2 1 Note The content...

Страница 4: ...iance The appliance shall be installed operated and stored in a room with a floor area larger than 4m Obey the installation instruction supplied with the appliance Always be careful when you move the appliance because it is heavy Always wear safety gloves Make sure the air can circulate around the appliance Wait at least 4 hours before connecting the appliance to the power supply This is to allow ...

Страница 5: ...umidifier MK200 dehumidifiers are easy to move around all you need to have is a power source for 220 240V but bear in mind the following The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight as it will reduce performance It is beneficial to use a radiator or heating fan to keep the temperature above 2 C The dehumidifier should stand at least 25cm ...

Страница 6: ...anted 5 Push the water tank home The float should now be in the tankr instead of being stuck behind it 6 Reconnect the dehumidifier to the power supply 3 3 Drainage of water The dehumidifier is fitted with a hose connection By attaching a hose to the dehumidifier the condensed water can be drained directly away 3 3 1 Using the hose 1 Disconnect the dehumidifier from the power source and remove the...

Страница 7: ...es the capacity of the dehumidifier and cleanses the air further Please refer to the separate filter leaflet for installation and maintenance instructions 3 6 Automatic defrosting MK200 dehumidifiers are fitted with a control unit which ensures that the cooling coils are defrosted automatically when needed The control shuts down the compressor which causes the cooling of the coils to stop The fan ...

Страница 8: ...intenance free Filter cleaning As the dehumidifying capacity is decreasing with a dirty filter it should be cleaned regularly This could be done either by using a vacuum cleaner washing with a mild detergent Replacement filters are available from your Munters Service Dehumidifier cleaning The front grill could be cleaned using a rap or vacuum cleaner If the inside of the unit is dirty it has to be...

Страница 9: ...Defrost cycle can take 35 minutes Check that there is no thick coating of ice forming on the cooling coils High noise level Increase distance between dehumidifier and surrounding objects Cooling coils may be touching each other and cause a ringing noise due to vibration Disconnect dehumidifier from power supply and separate coils Ice formation on cooling coils Remove air filter at rear of dehumidi...

Страница 10: ...ls Defrost automatically Electric control built in humidistat Display indication full water tank Condensate drain into water tank alternatively directly through drain connection 5 2 Warranty Warranty period is 24 months after delivery if nothing else has been agreed upon and documented This warranty is limited to free of charge replacements and delivery to delivery address of parts which are fault...

Страница 11: ...Operation Manual MK200 11 6 Wiring diagram ...

Страница 12: ...Operation Manual MK200 12 7 Explosion drawing ...

Страница 13: ...nser 9073700410 12 Drip tray 9073700411 13 Fan motor 9073700212 14 Float switch mounting clip 9073700412 15 Water tank 9073700413 16 Compressor 9073700414 17 Micro switch 9073700415 18 Fan blade 9073700233 19 Component carrier 9073700416 20 Carrier lid 9073700417 21 Circuit board sensor 9073700418 22 Adapter 9073700419 23 Knob 9073700420 24 Handle 9073700421 25 Adaptor hose Euro design 9073700422 ...

Страница 14: ...midifier type MK 200 are in conformity with the following directives 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2011 65 EU RoHS Directive and are manufactured in conformity with the following standards EN60335 1 2010 Fifth edition EN60335 2 40 2002 A1 2005 A2 2005 EN62233 2008 EN55014 2 1997 Munters GmbH Hamburg 15 10 2018 ______________ Place and date P Kruetzmann Head of order han...

Отзывы: