Munters JAZ 125 Скачать руководство пользователя страница 8

 

1.  Thermostat Control Knob 
2.  Green Indicator Light 
3.  On/Off Switch 
4.  Fuseholder 
5.  Power Cord Socket 

 

 
 
 
 

 
To Start the Heater 
 
1.  Turn  the  ON/OFF  switch  (3)  to  the  ON  (“I”) 
position.  The  green  indicator  light  above  the 
On/Off switch will flash slowly (every 3 seconds), 
indicating STAND-BY MODE.   
 
2.  Turn  the  thermostat  knob  slowly  clockwise 
until  the  heater  starts.  The  green  indicator  light 
above  the  On/Off  switch  will  remain  lit 
continuously, ON MODE. 

 

3.  Adjust  the  thermostat  to  the  desired 
temperature 

[setting/position?]

.  One  or  two 

adjustments  may  be  required  to  obtain  the 
desired 

temperature.When 

the 

thermostat 

senses  the  temperature  has  been  reached,  the 
heater  will  cycle  off  and  return  to  STAND-BY 
MODE.  The  thermostat  will  cause  the  heater  to 
automatically  turn  on  and  off  to  maintain  the  set 
temperature.

 

 
Note:    Air temperature and wind velocity around 
the  heater  may  affect  the  thermostat  operation.   
Adjustments  to  the  thermostat  setting  may  be 
required to obtain the desired comfort level.   
 

 

This heater is equipped with a 

thermostat.  When  in  the  STAND-BY  MODE, 
the heater may start at anytime on thermostat 
command.  Keep  children  and  animals  away 
from heater area at all times! 
 

 

Maintain  adequate  clearances 

from  combustible  materials  at  all  times 
during  operation.  See  "Minimum  Safety 
Clearances from Materials and Objects in  the 
Surroundings  of  the  Heater"  in  the  Electrical 
Connection and Installation section, above. 
 

 

Do  not  start  the  heater  if  the 

combustion  chamber  is  hot  or  if  excess  fuel 
has 

accumulated 

in 

or 

around 

the 

combustion 

chamber. 

Accumulated 

fuel 

could  result  from  repeated  unsuccessful 

ignition  attempts.  Unplug  heater  and  remove 
excess  accumulated  fuel  before  attempting 
restart. 
 

Never 

leave 

the 

heater 

unattended  while  burning  or  connected  to  a 
power source.   
 
4. To operate the heater in  “CONTINUOUS  ON” 
MODE, turn the thermostat knob fully clockwise.   
     
IMPORTANT:  If  the  heater  fails  to  start  the 
indicator  light  will  FLASH  rapidly  (four  times  per 
second) indicating LOCK-OUT MODE.           
If the heater goes into lock-out mode, check and 
remove  the  cause  of  lock-out  before  restarting 
the  heater.  See  Troubleshooting,  page…  To 
reset,  turn  the  ON/OFF  switch  to  0  and  then 
again  to  I.  If  repeated  LOCK-OUT  occurs,  call 
Customer Service (+1-239-936-1555).   
NOTE  1:  turning  the  thermostat  knob  will  NOT 
reset the heater.   
NOTE 2: in case of power failure and restoration   

 

5.  ABNORMAL  OPERATION:  in  case  of 
malfunction  (flame  failure,  reduced  air  flow,  bad 
combustion,  etc.)  the  heater  stops  and  the 
indicator  light  starts  FLASHING  QUICKLY 
(LOCK-OUT MODE). 
 
6.  POWER  FAILURE:    in  case  of  power  supply 
failure, the green indicator light will not be lit and 
the  heater  must  be  manually  reset.  Turn  the 
On/Off switch to Off ("O") and then to the On ("I") 
position  to  restart  the  heater  as  power  supply  is 
restored.

 

 
To Stop the Heater 

 
1.  Turn the On/Off switch to OFF (“O”) position.   
2.    Unplug the heater.   
 

7.  Cleaning, 

Maintenance 

and 

Storage   

 
Regularly wipe the enclosure using a soft sponge 
or  cloth.  For  very  dirty  parts,  use  a  sponge 

Fig. 7 

Содержание JAZ 125

Страница 1: ...erosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160 IMPORTANT Read and understand this manual before assembling starting or servicing the heater Improper use of this heater can cause serious injury Keep this manual for future reference JAZ ...

Страница 2: ...ntities dimensions etc for production or other reasons subsequent to publication While we believe the information is accurate and complete we make no warranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion an...

Страница 3: ... not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Not for home or recreational vehicle use Local laws and regulations may limit or prohibit the use of this type of heater Consult your local fire department for further information Combustion by products produced when using this product contain carbon monoxide a chemical known to the Stat...

Страница 4: ... 65 gph 0 65 gph 0 85 gph 1 00 gph Voltage 120V 60Hz Electrical Power W 180 230 230 240 430 Air Pressure Setting psi 4 8 4 1 4 1 5 1 5 5 Current Rating A 1 50 2 00 2 00 2 05 3 15 Fuse rating A T 4A T 4A T 4A T 4A T 4A Dimensions Net Weight lb 27 3 30 4 34 6 58 9 62 2 ength in 26 4 26 4 32 0 36 6 36 6 Width in 12 5 12 5 17 7 20 5 20 5 Height in 16 5 16 5 24 4 25 0 25 0 Tank Capacity gal 5 0 5 0 5 0...

Страница 5: ... cap nuts to secure them Attach support bracket 14 screwing the knurled nut 13 to the tank drain cap Finger tighten firmly JAZ 125 List of contents Description Qty 1 Axle 1 2 Axle bracket 2 3 Spacer 2 4 Wheel D 200 2 5 Cap nut 2 6 Screw M5x16 4 7 Washer D 5 12 8 Nut M5 12 9 End cap 2 10 Rear handle 1 11 Front handle 1 12 Screw M5x30 8 not used on JAZ 125 Before adding fuel installation and use ass...

Страница 6: ...ver use this heater in living or sleeping areas Do not cover the heater Do not block the air inlet and outlet Do not attach ducting to this heater Install the heater upright on a flat level surface 1 Provide adequate clearance to combustible materials MINIMUM SAFETY CLEARANCES FROM MATERIALS INCLUDING COMBUSTIBLE MATERIALS AND OBJECTS IN THE SURROUNDINGS OF THE HEATER Sides 2 ft Air inlet 3 ft Top...

Страница 7: ...ltage must be 120 V 10 108 V 132V Do not connect the heater to the generator if the voltage is not within this range The installation of the equipment shall be in accordance with the regulations of authorities having jurisdiction and CSA B139 Do not connect the heater to external fuel tanks 6 Operation 1 Fill the fuel tank with clean 1 K Kerosene Fuel Oil Diesel Fuel No 1 or Fuel Oil Diesel Fuel N...

Страница 8: ...tion section above Do not start the heater if the combustion chamber is hot or if excess fuel has accumulated in or around the combustion chamber Accumulated fuel could result from repeated unsuccessful ignition attempts Unplug heater and remove excess accumulated fuel before attempting restart Never leave the heater unattended while burning or connected to a power source 4 To operate the heater i...

Страница 9: ...void your warranty RECOMMENDED MAINTENANCE SCHEDULE Fuel tank Drain and flush fuel tank using clean kerosene every 150 200 hours or as needed Nozzle Inspect and clean nozzle every heating season Unscrew nozzle from nozzle fitting Blow compressed air through nozzle orifice to free it from dirt particles Replace nozzle if needed Air intake and output filters Every 500 hours Inspect air filters Remov...

Страница 10: ...nt screw clockwise to increase or counterclockwise to decrease the pressure Tighten the hex nut and remove the hex key from the adjustment screw Check the pressure shown on the pressure gauge again and repeat the procedure as required to obtain the correct air pressure Model Air Pressure psi JAZ 42 4 8 JAZ 80 4 1 JAZ 80 W 4 1 JAZ 125 5 1 JAZ 160 5 5 Electrical Inspect all internal wiring electrica...

Страница 11: ...place spark electrode Fuel nozzle clogged Clean nozzle by blowing compressed air through front of nozzle replace if necessary Heater stops during operation GREEN INDICATOR LIGHT SLOWLY FLASHING 1 flash 4 seconds The desired room temperature has been reached Heater is in STAND BY MODE No fault Normal operation To start turn thermostat knob clockwise to a higher setting GREEN INDICATOR LIGHT NOT LIT...

Страница 12: ...t cause of overheating If needed call Customer Service Faulty or Dirty Photocell Flame Sensor Clean or replace photocell Faulty Control Board Replace control board For Spot Climate Control Customer Service 9 am to 5 pm EST Call 239 936 1555 and select SCC Customer Service ...

Страница 13: ...ng Syst Co Ltd Phone 966 1 477 15 14 Fax 966 1 476 09 36 Korea Munters Korea Co Ltd Phone 82 2 761 8701 Fax 82 2 761 8777 Mexico Munters Mexico Phone 52 722 270 40 30 Fax 52 722 270 41 95 Norway via sales organization in Sweden South Africa and Sub Sahara Countries Munters Pty Ltd Phone 27 11 997 2000 Fax 27 11 608 3501 Spain Munters Spain S A Phone 34 91 640 09 02 Fax 34 91 640 11 32 Sweden Munte...

Отзывы: