Define at least one analog sensor as a potentiometer in
Install > Analog Sensor
(
page 109).
1. Select a potentiometer number.
2. Press Enter.
The device relay closes and then opens. As this takes place, the numbers in the Close, Current, and
Open columns change. After a few minutes, the process completes and a "Good Calibration"
message appears.
NOTE:
After potentiometer calibration, the times displayed in the Vent/Curtain Setup screen change.
Refer to Vent & Curtain Levels, page 41 for details.
9.9
Nipple Flushing
NOTE:
Broiler/Layer Mode supports this function.
To use this selection, program the water solenoids using the following relay codes:
•
111 Water Main: The control's supplementary for the usual water line
•
112 Water Bypass: The control's supplementary to bypass the water pressure regulator
•
113 Water line 1 through 122 Water line 10: Individual water line supplementary to select
the line to flush
During normal operation, only relay 111 water main is active. During flushing relay, code 112 is active
together with each of the individual water line relays in turn.
•
Configure up to 20 flush times.
•
Set start time/duration of water flushing (water lines as defined by relay layout)
9.9.1
N
IPPLE
F
LUSHING
H
ELP
|
S
ET
D
EFINITIONS
While viewing the
Nipple Flushing
menu: Press
HELP
, select SET, and press
ENTER.
•
Flush Order: Set flushing according to line/order
•
Flushing Days: Set flushing per day using '+/-' key
NIPPLE FLUSHING
Start
Time
On Time
(min)
Status
06:00 2
AUTO
15:40 1
AUTO
00:00 0
AUTO
00:00 0
AUTO
00:00 0
AUTO
FLUSH ORDER
Line:
1
2
3
4
--
--
--
Order:
1
2
3
4
--
--
--
FLUSHING DAYS
Day:
Sun Mon TUE WED THU FRI SAT
Flush: ▪
√
√
▪
▪
▪
▪