CAUTION
If you want to provide feed every day, select Daily. Selecting Week and marking each
day causes problems with this function.
If you select the 2 – 6 Day schedule or the Week schedule, configure:
•
Days Cycle (2 – 6 Days): Select which days in the cycle that feed and water is delivered.
•
Week Cycle: Select the days that feed and water is delivered.
•
Water on No Feed Days: Select up to two time periods when water is delivered on non-feed
days.
NOTE:
On feed days, water is delivered when feed is delivered.
4.10
Extra Systems
This menu sets the parameters of other devices that are not listed in the controller.
•
Start Time: Time at which this Extra System starts.
•
End Time: Time at which this Extra System stops.
•
From Temp: Temperature above which Extra System operates.
•
To Temp: Temperature below which Extra System operates.
•
From Humidity: Humidity above which Extra System operates
•
To Humidity: Humidity below which Extra System operates.
•
On (sec): On time for the Extra System. If set to 0, the extra system does not operate.
•
Off (sec): Off time for Extra System after completion of on time. If you have values in both ON
and Off, the extra system cycles. If you have zero OFF time, and any ON time, the system
simply stays on as long as the other parameters are satisfied.
NOTE:
All parameters must be satisfied for an Extra System to operate. For example if the
temperature is below the From Temperature or the Humidity below the From Humidity, the
system is OFF. You can assign specific temperature sensors to an Extra System in
Install | Temp
Definition
. The Extra System uses the Inside Humidity, not the Outside Humidity. If there is no
humidity sensor, the Extra Systems ignore the humidity parameters.
4.11
Emergency Setting
This selection applies to optional emergency cards. These cards are battery backed, and operate as
standard switch and relay cards during normal operation. If an emergency occurs, the cards continue to
operate according to their emergency settings
.
This function requires installing an Emergency card.
EXTRA SYSTEMS
System
1
2
3
4
Start Time
End Time
From Temp
To Temp
From Hum.
To Hum.
On (sec)
Off (sec)
10:30
18:45
75.5
93.0
55
85
45
300
06:15
20:30
85.5
95.5
60
85
45
300
14:20
03:15
60
98.0
60
85
300
2000
00:00
00:00
0.0
0.0
0
0
0
0