![Munters Farm P-XL Скачать руководство пользователя страница 108](http://html.mh-extra.com/html/munters/farm-p-xl/farm-p-xl_user-manual_1856887108.webp)
© Munters AB, 2015
108
10.2.1
O
UTPUT
F
UNCTION
L
IST
Relay Name
Quantity Supported
1.
Heaters
16
2.
Radiant Heaters Low
16
3.
Radiant Heaters High
16
4.
Radiant Heaters Ignite
16
5.
Tunnel Fan
30
6.
Exhaust Fan
20
7.
Stir Fan
15
8.
Cooling
4
9.
Cooling Pad
4
10.
Fogger
4
11.
Vent Open
4
12.
Vent Close
4
13.
Tunnel Open
4
14.
Tunnel Close
4
15.
Curtain Open
4
16.
Curtain Close
4
17.
Attic Open
1
18.
Attic Close
1
19
Vent Speed
1
20.
Light
4
21.
Water
4
22.
Feeder
4
23.
Auger
4
24.
Extra System
4
25.
Alarm (N.C.)
1
26.
Fail Safe (N.C.)
1
27.
Feeder Win Open
1
28.
Feeder Win Close
1
29.
Feeder Line Up
1
30.
Feeder Line Down
1
31.
Drink Line Up
1
32.
Drink Line Down
1