background image

 

 

  

  

PT 

Qw 

Δpw 

Tp2 

PT 

Qw 

Δpw 

Tp2 

Tp1 

kW 

l/h 

kPa 

°C 

kW 

l/h 

kPa 

°C 

°C  m

3

/h 

Tw1 / Tw2 = 90/70

o

Tw1 / Tw2 = 80/60

o

3200/

3500

/400

20,9/21,9/23,5 

923/968/1039 

5,9/6,5/7,4 

19,6/18,5/17,5 

17,8/18,7/20,0 

783/821/881 

4,5/4,9/5,6 

16,5/16,0/15,0 

19,6/20,5/22,0 

863/905/972 

5,3/5,6/6,6 

23,0/22,5/21,5 

16,4/17,3/18,5 

722/758/813 

3,9/4,3/4,9 

20,0/19,5/18,5 

10 

18,2/19,1/20,5 

803/842/904 

4,6/5,0/5,7 

27,0/26,0/25,0 

15,0/15,8/17,0 

662/694/745 

3,3/3,6/4,1 

24,0/23,0/22,5 

15 

16,8/17,6/19,0 

742/779/835 

4,0/4,4/5,0 

30,5/30,0/30,0 

13,7/14,3/15,4 

601/630/676 

2,8/3,0/3,5 

27,5/27,0/26,5 

20 

15,5/16,2/17,4 

682/715/767 

3,4/3,7/4,2 

34,0/33,5/32,5 

12,3/12,9/13,8 

539/566/607 

2,3/2,5/2,8 

31,0/30,5/30,0 

  

  

Tw1 / Tw2 = 70/50

o

Tw1 / Tw2 = 70/40

o

3200/

3500

/400

14,7/15,4/16,5 

642/674/723 

3,3/3,6/4,0 

13,5/13,0/12,5 

11,5/12,1/13,0 

335/352/378 

1,0/1,1/1,3 

10,5/10,0/9,6 

13,3/13,9/15,0 

581/610/655 

2,7/3,0/3,4 

17,5/16,5/16,0 

10,1/10,5/11,3 

293/307/330 

0,8/0,9/1,0 

14,5/14,0/13,5 

10 

11,9/12,5/13,4 

520/546/585 

2,2/2,4/2,8 

21,0/20,5/20,0 

8,6/9,0/9,7 

249/262/281 

0,6/0,7/0,8 

18,0/17,5/17,0 

15 

10,5/11,0/11,78 

458/481/516 

1,8/1,9/2,2 

24,5/24,0/23,5 

7,0/7,3/7,9 

202/213/230 

0,4/0,5/0,5 

21,5/21,0/20,5 

20 

9,0/9,5/10,2 

395/415/445 

1,4/1,5/1,7 

28,0/27,5/27,5 

5,1/5,4/6,0 

147/158/173 

0,2/0,3/0,3 

24,5/24,5/24,0 

  

  

Tw1 / Tw2 = 60/40

o

Tw1 / Tw2 = 50/40

o

3200/

3500

/400

11,5/12,0/13,0 

500/525/563 

2,2/2,4/2,7 

10,5/10,0/9,5 

11,5/12,0/13,0  1001/1050/1128 

7,7/8,4/9,5 

10,5/10,0/9,5 

10,1/10,5/11,5 

438/460/494 

1,7/1,9/2,1 

14,5/14,0/13,5 

10,1/10,6/11,4 

878/922/990 

6,1/6,6/7,5 

14,5/14,0/13,5 

10 

8,6/9,0/9,7 

375/394/423 

1,3/1,4/1,6 

18,0/17,5/17,0 

8,7/9,1/9,8 

755/793/851 

4,6/5,0/5,7 

18,0/17,5/17,0 

15 

7,1/7,5/8,1 

311/327/351 

0,9/1,0/1,1 

21,5/21,0/21,0 

7,3/7,6/8,2 

631/662/711 

3,3/3,6/4,1 

21,5/21,5/21,0 

20 

5,6/5,9/6,3 

243/256/276 

0,6/0,7/0,7 

25,0/24,5/24,5 

5,8/6,1/6,5 

505/530/568 

2,2/2,4/2,8 

25,5/25,0/24,5 

 

  

  

PT 

Qw 

Δpw 

Tp2 

PT 

Qw 

Δpw 

Tp2 

Tp1 

kW 

l/h 

kPa 

°C 

kW 

l/h 

kPa 

°C 

°C  m

3

/h 

Tw1 / Tw2 = 90/70

o

Tw1 / Tw2 = 80/60

o

4000/

4300

/520

0

 

27,6/28,7/31,8  1217/1266/1402  11,4/12,2/14,7  20,5/19,5/18,0 

23,6/24,6/27,7 

1038/1080/1195 

8,7/9,4/11,3 

17,5/17,0/15,5 

25,8/26,9/29,7  1140/1186/1312  10,0/10,8/13,0  24,0/23,5/22,0 

21,9/22,7/25,2 

961/999/1106 

7,6/8,2/9,8 

21,1/20,5/19,5 

10 

24,0/25,0/27,7  1063/1105/1223 

8,9/9,5/11,5 

27,5/27,0/25,7 

20,1/20,9/23,1 

883/918/1016 

6,5/7,0/8,4 

25,0/24,5/22,5 

15 

22,3/23,2/25,7 

985/1024/1133 

7,7/8,3/10,0 

32,5/30,5/29,5 

18,3/19,0/21,0 

804/836/925 

5,5/5,9/7,1 

28,5/28,0/27,0 

20 

20,5/21,4/23,6 

907/943/1043 

6,6/7,1/8,8 

35,0/34,5/33,0 

16,5/17,2/19,0 

725/754/834 

4,6/4,9/5,9 

32,0/31,5/30,5 

  

  

Tw1 / Tw2 = 70/50

o

Tw1 / Tw2 = 70/40

o

4000/

4300

/520

0

 

19,7/20,5/22,5 

860/894/990 

6,4/6,9/8,3 

14,5/14,0/13,0 

16,1/16,7/18,5 

468/487/538 

2,2/2,3/2,8 

12,0/11,5/10,5 

17,9/18,6/20,5 

782/813/900 

5,4/5,8/6,9 

18,0/17,5/17,0 

14,3/14,8/16,4 

414/431/477 

1,8/1,9/2,3 

15,5/15,0/14,5 

10 

16,1/16,7/18,5 

703/731/809 

4,5/4,7/5,7 

21,5/21,5/20,5 

12,4/12,9/14,2 

360/374/414 

1,4/1,5/1,8 

19,0/19,0/18,0 

15 

14,5/14,8/16,4 

624/649/717 

3,6/3,8/4,6 

25,5/25,0/24,5 

10,4/10,9/12,0 

304/316/350 

1,0/1,1/1,3 

22,5/22,5/21,5 

20 

12,4/12,9/14,3 

544/565/625 

2,8/3,0/3,6 

29,0/28,5/28,0 

8,4/8,8/9,6 

245/256/284 

0,7/0,7/0,9 

26,0/26,0/25,5 

  

  

Tw1 / Tw2 = 60/40

o

Tw1 / Tw2 = 50/40

o

4000/

4300

/520

0

 

15,6/16,3/18,0 

681/708/784 

4,6/4,7/5,6 

11,5/11,0/10,5 

15,3/15,9/17,6 

1327/1380/1529  14,8/15,9/19,2  11,5/11,0/10,0 

13,8/14,4/15,9 

602/626/693 

3,5/3,7/4,5 

15,0/15,0/14,0 

13,5/14,0/15,5 

1170/1217/1348  11,8/12,7/15,2  15,0/14,5/13,5 

10 

12,0/12,5/13,8 

522/543/601 

2,7/2,9/3,5 

18,5/18,5/18,0 

11,6/12,1/13,4 

1012/1052/1165 

9,1/9,7/11,7 

18,5/18,5/17,5 

15 

10,1/10,5/11,6 

441/458/507 

2,0/2,1/2,6 

22,5/22,0/21,5 

9,8/10,2/11,3 

852/886/981 

6,6/7,1/8,6 

22,5/22,0/21,5 

20 

8,2/8,5/9,5 

357/372/412 

1,4/1,5/1,8 

26,0/25,5/25,0 

7,9/8,3/9,1 

690/718/794 

4,6/4,9/5,6 

25,5/25,5/25,0 

 

 

 

MU-EMP-15-W

MU-EMP-20-W

7

 

 

 

V - Air flow

PT - Heating capacity

Tp1 - Inlet air temperature

Tp2 - Outlet air temperature

Tw1 - Inlet water temperature

Tw2 - Outlet water temperature

Qw - Heating water stream

pw - water pressure

Δ

V - Caudal de aire 

PT - Capacidad de calefacci

ó

Tp1 - Temp. de entrada de aire 

Tp2 - Temp. de salida de aire 

Tw1 - Temp. de entrada de agua 

Tw2 - Temp. de salida de agua 

 Qw - Caudal de agua caliente 

Δ 

pw - presión de agua 

Содержание MU-EMP Series

Страница 1: ...EC06700 EC06711 www mundoclima com MU EMP A W W2F R3...

Страница 2: ...make changes in the device without influencing its operation 2 NDICE 1 INFORMACI N GENERAL 3 2 ESPECIFICACIONES T CNICAS 4 2 1 MATERIALS 4 2 2 DIMENSIONES 5 2 3 NIVEL DE PRESI N AC STICA 5 2 4 CAUDAL...

Страница 3: ...urtain with electric heat exchanger max range 5m 3 1 INFORMACI N GENERAL 5m El prop sito de MU EMP es minimizar las p rdidas de calor no deseadas por las aberturas de la puerta MU EMP es una unidad em...

Страница 4: ...EMP 15 W MU EMP 15 A MU EMP 15 12 R3 MU EMP 20 W MU EMP 20 A MU EMP 20 16 R3 10 W2F 15 W2F 20 W2F 4 MU EMP R3 Temperature increase at inlet air 10 C MU EMP W W2F Temperature increase at inlet air 10...

Страница 5: ...or MU EMP A R3 MU EMP 10 W MU EMP 10 8 R3 MU EMP 10 W2F MU EMP 10 A MU EMP 15 A MU EMP 15 W MU EMP 15 12 R3 MU EMP 15 W2F MU EMP 20 A MU EMP 20 W MU EMP 20 16 R3 MU EMP 20 W2F MU EMP 5 2600 m3 h 2500...

Страница 6: ...1 18 0 17 5 17 5 20 4 7 5 0 5 1 204 220 225 0 3 0 4 0 4 26 0 25 5 25 0 1 8 1 8 1 8 51 53 53 0 1 0 1 0 1 22 5 22 0 22 0 Tw1 Tw2 60 40o C Tw1 Tw2 50 40o C 0 2200 2500 2600 6 2 6 6 6 8 269 289 295 0 6 0...

Страница 7: ...7 1266 1402 11 4 12 2 14 7 20 5 19 5 18 0 23 6 24 6 27 7 1038 1080 1195 8 7 9 4 11 3 17 5 17 0 15 5 5 25 8 26 9 29 7 1140 1186 1312 10 0 10 8 13 0 24 0 23 5 22 0 21 9 22 7 25 2 961 999 1106 7 6 8 2 9...

Страница 8: ...0 35 0 33 0 31 2 32 5 36 0 1370 1425 1580 3 6 3 8 4 6 31 0 30 0 28 0 5 34 2 35 6 39 4 1509 1570 1740 4 1 4 4 5 4 38 5 38 0 35 5 28 8 29 9 33 2 1264 1314 1457 3 1 3 3 4 0 33 5 32 5 31 0 10 31 8 33 1 39...

Страница 9: ...25 4 63 5 75 29 29 27 24 2 25 4 28 6 1057 1107 1248 2 75 2 99 3 71 24 23 22 10 28 2 29 5 33 3 1233 1292 1456 3 51 3 82 4 74 32 31 30 21 0 22 0 24 8 916 960 1082 2 13 2 32 2 87 26 26 25 15 25 0 26 2 2...

Страница 10: ...5 6 7 8 9 10 11 12 10...

Страница 11: ...valves with actuator speed controller BMS connection optional equipment 5 CONTROL SYSTEMS 11 5 SISTEMAS DE CONTROL CONTROL DRV Conexi n de cortinas controla hasta 5 unidades con un control Conexi n al...

Страница 12: ...5 1 CONNECTING GUIDE 1 2 3 4 5 6 7 8 MU EMP R3 MU EMP A W W2F 12 5 1 GU A DE CONEXI N...

Страница 13: ...STEMA DE CONTROL DRV EMP 1 2 3 4 5 6 MU EMP A W W2F MU EMP R3 Programa K1 La se al del interruptor de la puerta o del termostato es la se al principal para que funcione la unidad Programa K2 La se al...

Страница 14: ...g Valve CO13251 252 CO13254 255 Thermostat SE 3 CO14653 CL91188 CL91190 14 5 2 1 ESQUEMA EL CTRICO SE 3 MU EMP A W W2F Alimentaci n el ctrica 230 V 50Hz OMY 3x1mm 2 Termostato SE 3 CO14653 Contacto de...

Страница 15: ...ermostat SE 3 CO14653 CL91188 CL91190 3 2 1 4 7 6 5 Low Med Hig MU EMP 15 12 R3 MU EMP 20 16 R3 15 5 2 2 ESQUEMA EL CTRICO SE 3 MU EMP R3 Alimentaci n el ctrica 3x400V 50Hz MU EMP 10 8 R3 m n 5 x 2 5...

Страница 16: ...4 255 CL91188 CL91190 T box OMY 4x0 5mm2 CL91182 o 16 5 2 3 ESQUEMA EL CTRICO T box MU EMP A W W2F Alimentaci n el ctrica 230 V 50Hz OMY 3x1mm 2 T box OMY 4 x 0 5 mm 2 CL91182 Contacto de la puerta DC...

Страница 17: ...acts closed OMY 2x0 5mm2 CL91188 CL91190 MU EMP 15 12 R3 MU EMP 20 16 R3 17 5 2 4 ESQUEMA EL CTRICO T box MU EMP R3 Alimentaci n el ctrica 3 x 400 V 50 Hz MU EMP 10 8 R3 m n 5 x 2 5 mm 2 Sobrecorrient...

Страница 18: ...NICATION 5 2 6 CONTROL SYSTEM DRV CHAINING 18 5 2 5 SISTEMA DE CONTROL COMUNICACI N M STER ESCLAVA El sistema en red de cortina de aire el ctrica controla de 1 a 5 uds usando un SE 3 y DC El sistema e...

Страница 19: ...ador DRV tiene la posibilidad de conectarse al Sistema Gesti n de Edificios BMS La conexi n se puede hacer de dos maneras 1 Para la placa de circuito impreso de DRV en caso de func sin T box 2 Al cont...

Страница 20: ...TEM SETTING BMS ADDRESS 20 5 2 8 SISTEMA DE CONTROL AJUSTE DE DIRECCIONES BMS Cuando se conectan m dulos DRV al controlador T box o BMS se deben establecer direcciones binarias en cada m dulo DRV cada...

Страница 21: ...he device for a longer period of time the exchanger tubes should be emptied with compressed air 21 Antes de conectar la fuente de alimentaci n comprobar que la conexi n de los controles es correcta Es...

Страница 22: ...opening 22 10 LIMPIEZA Y CONSERVACI N El intercambiador lleno de suciedad causa la salida de calor interna y la ca da del flujo de aire Si es necesario limpiar el intercambiador de calor use las pauta...

Страница 23: ...Provenza 392 P2 08025 Barcelona Spain e mail info mundoclima com www mundoclima com P ngase en contacto con su proveedor para conocer los t rminos de la garant a y sus limitaciones En caso de irregul...

Страница 24: ...www mundoclima com C PROVENZA 392 P2 08025 BARCELONA SPAIN 34 93 446 27 80...

Отзывы: