12 - TECHNICAL DATA
Size
200
300
200S 300S
Ventilation
Type of fan
Centrifugal
Air flow
m
3
/h 270
414
270
414
Available pressure head
Pa
25
25
25
25
Integration
Solar coil surface
m
2
- -
1,10
1,30
Solar coil material
Enamel
Steel
bar
10
10
MPa
1 1
Maximum operating pressure
1. Inlet water temperature 15 °C, accumulator set 45°C, air on source side 15°C D.B /12°C W.B.
2. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Average Climate, Heat Pump Water Heater
3. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Warmer Climate, Heat Pump Water Heater
4. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Colder Climate, Heat Pump Water Heater
5. Data referred to completely ducted unit.
6. Maximum temperature that can be reached during Anti-legionella mode(Dinsifect)
*It contains fluorinated greenhouse gases
OPERATING LIMITS
Size
200
300
200S
300S
Power supply (1)
V
220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
F.L.A. - Current absorbed at the maximum allowed conditions
A
9,10 9,80 9,10 9,80
F.L.I. - Power absorbed at full load (at the maximum allowed condi-
tions)
kW
2,10 2,25 2,10 2,25
M.I.C - Maximum inrush current
A
22,2 33,7 22,2 33,7
ELECTRICAL DATA
1) Power supply 220-240/1/50 Hz
For power voltages other than the standard, contact the technical department
The units are conforming with the prescriptions of European Standards CEI EN 60204 and CEI EN 60335
Warning: when defining the correct size, verify that all absorption is compliant with current electrical supply
contracts in force in the country of installation
300 - 300S
1. Use range of the heat pump
2. Use range of the electrical heating element
3. Use range of the electrical heating element only in Anti-Legionella mode
(Disinfect)
Twu [°C] water temperature in the accumulator
Tae [°C] air temperature at exchanger inlet
200 - 200S