Electric connection
1. Take down the upper corer and wring cover of electrical box.
2. For KF(R)-28GJW/A300 KF(R)-35GJW/A300,KF(R)-40GJW/A300, first connect the blue wire of the power
connection cable to the terminal “N(1)”, the brown one to “2”,the red one to 3(for KF(R)-40GJW/A300), the
yellow-green one (earthing wire) connect to “ ”, as shown in figture A and Figture b.
3.Reassemble the wiring cable and upper cover of electrical box, wiring the wiring clamp to clasp the connec-
tion wire. There should be some space between the wire.
Noices:
All the electrical work must be done by qualified personnel according to be local rules and this manual.
The rated votlage and exclusive the unit must be used.
Be sure to install leakage circuit breaker.
Please choose the specified fuse.
The diameter of power cable should be large enough, use the exclusive wire to replace the damaged wire.
Wiring work should confirm to the national standard.
wiring terminal board
Signal control
wire
connection
wire clamp
Fig. A
screw
fixed screw
connection
installation
wire clamp
power cable
power connec-
tion cable
upper corer of
electrical box
installation corer
of electrical box
Fig. B
Fig. C
(Use only for heat
pump type)