-- 27 --
The installation of indoor unit
1.first take off the air filter and the upper cover of electrical box before installation.
2.Hold the big handle then place indoor units on the hook of wall mountaing frame.
Notice:
Avoid the damage caused by the air conditioner collapse into the wall.
Don’t clamp the louver
3.Move the air-conditioner in all directions, ensure they are held tightly.
4.Fix the two position with screw as picture B shows.
5.The installation height of indoor unit must be more than 2 meters high.
Installation of drain hose
1.Be sure the drainage hose must be placed slightly down
for the sake of convenient drainage.
2.Don’t place it with heave,swirl and don’t intrude into
into water.
3.You should use heat insulation material when connect
long drain hose.
4.The drainage panel has two waterspout,you can chose which one to drain the water according to actual
installation.If the location is different, you can exchange the installation of drainage pipe and blockage.
Installation of drain hose
Connect the connection pipe and two outlet pipe of indoor unit, fastening the terminal nut of the former.
Air outlet grill
Louver
Screw(ST4.2
25)
Big handle
Hook
Fig. A
Fig. B
Heave
Bent
Don’t intrude
into water
Notice
Connect the connection pipe with the indoor unit firstly and the outdoor unit secondly.
Be careful in bending the connection pipes, or you will damage the pipes.
If the tightening torque is too much in tiphtening in the flame nuts, leakage will happen
Wrap the connection place by specific heat freservation.
Filter
Hook