7.10. Comfort control system maintenance
7.10.1. Manual calibration of the speed sensor
1. First, select User setup (2. User setup) on the user interface Setup screen and then Seed
drill (6. Drill Setup).
Figure. 7.10.1. - 236. Calibration start screen in the user interface
2. Move the cursor to Speed sensor (SSF) (1) with the arrow buttons and press the OK
button (2).
The rst number starts to ash.
3. Change the value by pressing the up/down arrow buttons.
4. Con rm the value by pressing the right arrow button.
5. Repeat steps 3-4 for other numbers.
6. Con rm the correction by pressing the OK button (2).
7.10.2. Calibration of the speed sensor while driving
1. Select User setup and Seed drill on the user interface.
Figure. 7.10.2. - 237. Calibration start screen in the user interface
2. Move the cursor to Speed sensor (SSF Autocal) (1) and press the OK button (2).
Operation and maintenance manual
Cerex 300 and Cerex 400 Comfort
1.00
170 (187)
Содержание Cerex 300 Comfort
Страница 179: ...Hydraulic schematics Cerex 300 and Cerex 400 1 Hydraulic schematics Cerex 300...
Страница 180: ...Hydraulic schematics Cerex 300 and Cerex 400 2...
Страница 181: ...Hydraulic schematics Cerex 300 and Cerex 400 3 Hydraulic schematics Cerex 400...
Страница 182: ...Hydraulic schematics Cerex 300 and Cerex 400 4...
Страница 183: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 1 Electrical schematics...
Страница 184: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 2...