Figure. 6.8.4. - 129. Calibration test calibration values - machine with dual gearbox
The old calibration value (1), new calibration value (2), difference between the old
and new value (as a percentage) (3) and maximum feed rate (4) are displayed on
the screen.
18. Press the OK button (5).
19. Insert the cotter pins.
20. Turn the crank to bring the calibration trays to the seeding position.
21. Put the transmission cover back in place.
6.8.5. Seed calibration test in a machine without a gearbox
DANGER
Shut off the tractor, remove the key from the ignition and engage the parking brake
before running a calibration test. If the machine is equipped with middle markers, close
the middle marker shut-off valves in accordance with section 3.4. Using the middle
1. Raise the transmission cover.
Figure. 6.8.5. - 130. Seed calibration test in a machine without a gearbox.
Operation and maintenance manual
1.00
Cerex 300 and Cerex 400 Comfort
101 (187)