background image

All digit segment will be turned ON for 3 sec 

Previous or default sensor input will be displayed for 2 sec

Process Value
Set Value

POWER ON











ENT

SET

UTC 122

TUNE

ºC

PV

SV

 



1

7

8

9

12

13

14

10

11

16

17

18

19

20

15

2

3

4

5

6

NC

NC

C

C

NO

NO

TC

+

-

+

-

RELAY-1

RELAY-2

 

100 
250V AC

~

 

50/60 Hz
4VA

!

L

N

O/P

S.S.R

RTD

www.multispanindia.com

Page - 1

UTC-122,222

Note:

 1)

 

If Sensor Connection is reversed, Display will show “



” message.

 2) If Sensor is not connected, Display will show 



 message.

 3) Every time the instrument is turned ON, Following pattern will be displayed

              J: 0 to 600°C / K: 0 to 1200°C / 
PT-100: -99 to 400ºC /PT.1: -99.0 to 400.0°C

PID/ ON-OFF (selectable)

Output 

 Power Supply

 Protection Level

    Operating

    Relative

 (As per request)

 Temperature

   Humidity

          1st Output for Heating : 1Relay 1C/O,230V AC ,5A Or SSR,12V DC Approx,30mA
          2nd Output for Cooling : 1Relay 1C/O,230V AC ,5A

100 to 250V AC, 50 / 60 Hz, Approx 4VA 

IP-65(Front side) AS per IS/IEC 60529:2001

0°C To 55°C

Up to 95% RH Non Condensing

Model

Display

Size(HXWXD)
Panel Cutout

Input

Temperature 
      Range

Control Action

UTC 122

96 X 96 X 50 mm

92 X 92  mm

68 X 68 mm

72 X 72 X 85 mm

UPPER:- 4 Digit 7 seg 0.70”,red LED Display

LOWER:- 4 Digit 7 seg 0.50”,green LED Display

UTC 222

 J, K, PT-100 (selectable) 

Technical Specification  

Connection Diagram  

OPERATING MANUAL 

PID TEMPERATURE CONTROLLER                           

UTC-121P,221P & 421P

Technical Specification  

Connection Diagram  

OPERATING MANUAL 
UNIVERSAL TEMPERATURE CONTROLLER                           

UTC-122, 222 

TC

+

RTD

-

!

L

N

1

2

3

4

5

6

7

-

+

O/P

S.S.R

 RELAY-1

 RELAY-2

100  
250V AC
    

~

 

50/60 Hz
4VA

NC

NO

NO

NC

C

C

8

9

10

11

12

13

14

SET

  ENT

UTC 222

R1

R2

TUNE

PV

SV

ºC

 



Содержание UTC-122

Страница 1: ...ve As per request Temperature Humidity 1st Output for Heating 1Relay 1C O 230V AC 5A Or SSR 12V DC Approx 30mA 2nd Output for Cooling 1Relay 1C O 230V AC 5A 100 to 250V AC 50 60 Hz Approx 4VA IP 65 Front side AS per IS IEC 60529 2001 0 C To 55 C Up to 95 RH Non Condensing Model Display Size HXWXD Panel Cutout Input Temperature Range Control Action UTC 122 96 X 96 X 50 mm 92 X 92 mm 68 X 68 mm 72 X...

Страница 2: ... 1 Press key to go parameter setting 3 Press key to save change in setting 4 Press key for 6 sec to start stop PID AUTO TUNING 5 Press key for 3 sec to go to factory setting mode SET ENT 2 Press or key to change value or to select option Basic Configuration Set Point Setting Key Operation UTC 122 222 Press key to Save Exit ENT Control Action PID ON OFF Relay2 Mode TP ON OFF Set2 Mode Relative Indi...

Страница 3: ...apply factory set values as shown in table nO press key to escape from factory setting Press key for 3 sec UTC 122 222 PV SV Press key to save exit ENT Press key SET Manual Reset Proportional Band Integral Time Derivative Time Cycle Time PID Parameters ON OFF Parameters Hysteresis 1 Cool HYS Offset 20 0 C to 20 0 C 20 C to 20 C CT 4 sec to 99 sec 4 sec to 99 sec IT 0000 to 9999 0000 to 9999 Hyster...

Страница 4: ...in case the terminals do not remain accessible to the end user after installation and internal wiring 2 Do not allow pieces of metal wire clippings or fine metallic fillings from installation to enter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains switch must be installed between power source an...

Отзывы: