OPERATING MANUAL
SEQ. TIMER : 12 CHANNEL
Technical Specification
1) Model : SQT 1244
2) Display: 4 digit, Double Display
3) Input : NPN/PNP Proxy, Micro Switch.
4) Range :
1) 99.99 Sec.
2) 999.9 Sec.
3) 99.59 Min.
4) 99.59 Hrs.
5) 999.9 Hrs.
Mo
del : SQT 1044
Panel Cutout:
(96 X 96 mm)
(92 X 92 mm)
5) Relay Status : LED indicator
1) Relay status
2) Time unit
6) Timer Mode :
1) Delayed ON
2) Delayed OFF
3) Cycle Timer
7) Output : 12 Relay
8) Power Supply : 110 To 250V AC,
50/60 Hz SMPS
Note:
1) To make parameter setting easy, menu is devided in three groups.
2) Menu 1: is used to set the parameters which are needed to change
Frequently, like On time, OFF Time
3) Menu 2: is used to set the parameters like mode, range & No. Of cycles.
4) Menu 3: is used to set the parameters Which Needed to change in rare Case
like individual & Common mode, Type of input & memory retention.
Working:
SET
SET
1) First enter in menu-3 (Short Terminal No.8 & 10 ) Then Power On.
2) Configure The instrument As per Your Application
3) Press + Key & Follow Menu as per the Application.
4) Use & Key in Menu-1
5) At Any time press key to save and exit.
6) To Change Any parameter & Key.
7) To go to next parameter, Press Key.
8) If No. key is Pressed, Menu will Automatically exit after
15 SEC. without saving.
www.multispanindia.com
PAGE - 1
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
S
M
H
SQT- 1244
SEQ. TIMER
SET
ENT
RST
ENT
RST
1 2 3 4