MULTISPAN PID 2303-1C Скачать руководство пользователя страница 1

 PID CONTROLLER

PID 2303-1C 

PV = Process value

SV = Set value

INPUT SPECIFICATION:

Input Types

Resolution

Indication
Accuracy

Input  

Range

0 to 400°C

J,K = 1°C

±1% of FSD ± 1°C
(FSD:- full scale deflection)

DISPLAY AND KEYS: 

CONTROL METHOD:

DIMENSION:

Display

Heating

Size (mm) 

Cooling

Alarm

Panel Cutout

Upper: 4 digit, 7 seg 0.56” white LED

1) PID control with Auto-Tuning

Middle: 4 digit, 7 seg, 0.31” green LED  

2) ON-OFF control

72 (H) x 72 (W) x 85 (D) mm

68 (H) x 68 (W) mm

TECHNICAL SPECIFICATION

0 to 500°C

Lower: 3 digit, 7 seg, 0.39” red LED  

POWER SUPPLY:

ENVIRONMENT CONDITION:

Power Consuption
(VA Rating)

Relative Humidity

Protection Level

 Supply Voltage

 Operating Temp.

100 to 250V AC, 50-60Hz 

0°C to 55°C

UP to 95% RH 
(non-condensing)

IP-65 (Front side) As per IS/IEC
60529 : 2001

Approx 6VA @ 230V AC 

TERMINAL CONNECTION

MECHANICAL INSTALLATION

1 CT

0.0 to 30.0 A

1) BL.TP ( Blower Time Proportion)

Heater break alarm, Cold start, High, 
Absolute low, Inband, Absolute outband

2) ON-OFF control

72

85

68

68

3

72

Outline Dimension (mm)

Panel Cutout 
Dimension (mm)

SET

TUNE

OUT1
OUT2

AL

H

PV

SV

ºC

PID 2303-1C

3

2 4

235

45

1

2

8

9

10

11

12

13

14

L

N

!

H1

RELAY-3

RELAY-1

NO

NO

CT 
COM.

RELAY-2

-

+

TC

100  
250V AC
    

~

 

50/60 Hz
6VA

15

18

16

19

17

20

3

4

5

6

7

NO

S.S.R

-

+

C

NC

C

C

www.multispanindia.com

Made in India

Keys

SET, INC, DEC, ENT

OUTPUT SPECIFICATION:

Relays

Output Signal

Relay Type

Rating

3 Nos

24V DC, 30mA DC 
(On-Off condition)

Relay 1 parallel to SSR

st

nd

rd

1  Relay 1C/O & 2  & 3   Relay (NO-C)

10A,230V AC/28V DC

Relay Output

SSR Drive Output

Содержание PID 2303-1C

Страница 1: ...p 100 to 250V AC 50 60Hz 0 C to 55 C UP to 95 RH non condensing IP 65 Front side As per IS IEC 60529 2001 Approx 6VA 230V AC TERMINAL CONNECTION MECHANICAL INSTALLATION 1 CT 0 0 to 30 0 A 1 BL TP Blow...

Страница 2: ...ine metallic fillings from installation to enter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains...

Страница 3: ...ed or Sensor connection is reversed Over range condition or sensor break no no R2MD ALRM HBAL HBA HbI HIG H ON DT ABL OFF CT INB PB MR CS HTR IT Blower TP Action Hysterisis 2 Absolute Outband Alarm Re...

Страница 4: ...0 C Hysteresis 2 4 C to 99 C Pb2 Ct2 Mr2 Alarm Time Set 2 Offset HBAL HBI H 2 Control Mode ON OFF Relay turns ON and remains ON when PV SV Relay turns OFF when PV SV After this there may be overshoot...

Страница 5: ...If CS HIG ABL Select RLT Alarm time ALRM TIME 5 H I HB 1 H 0 0 aBL PARAMETER SETTING Alarm Alarm Mode Relative Individual time pass 73 INPT J h Input J K R1MD HEAT PID ONF HYS1 3 R2MD COOL B TP ONF S...

Страница 6: ...n Integral Time Derivative Time Cycle Time Manual Reset Proportional Band 2 Cycle Time 2 Manual Reset 2 Relay 3 Mode Alarm off pass 37 Case 3 INB ABO SET3 LOW 75 SET3 HI H 125 Set Point 3 Low Set Poin...

Страница 7: ...is a continuous process So for more updated operating information and Support Please contact our Helpline 9081078681 9081078683 or Email at Ver 2103 service multispanindia com ALARM OPERATION R3 Alar...

Отзывы: