MULTISPAN OC 99 Скачать руководство пользователя страница 1

OPERATING MANUAL 

CURRENT CONTROLLER
OC 99

www.multispanindia.com

Page - 1

 

Technical Specification:

Reset Key

M: Glows when power is on.

O/C : Glows when overloads

U/C : Glows when underloads
                                     (Dry run)

DISPLAY LED:

1)  Micro Controller Based.
2)  Size: 27 X 76 X 116 mm
3)  Supply: 230V AC   10%, 50Hz
4

  

 

±

)  Input : 0 To 30 Amp AC (Inbuilt CT).

5)  Output : 1 Relay 1 C/O ,5 Amp at 230V AC
6)  Knob for over current & under current setting
7) Din rail mounting.

This key is used to manual reset the relay.

INITIAL DELAY TIME:

       Initial Delay time is fixed to 7 Sec. So, no action would take place during this period.    

RST

UNDER CURRENT SETTING: 

OVER CURRENT SETTING :

          

 lower Knob is provided for set under current value range from 25 T0 90%

          of over current.

          

 Upper Knob is provided for set Current value range from 4 T0 30mA.

4

17

11

23

30

Over Current

Under Current

M

   O/C

   U/C

90

%

%

25

OC 99

RST

N

L

C

NC

NO

CUT

70

50

Отзывы: