Multireg LCD2 is an electronic thermostat with four functions.
Room sensor, floor sensor, power regulator and maximum /
minimum limiter. The thermostat has a backlit LCD-display and
weekly programming.
CONNECTING THE THERMOSTAT
The thermostat must be connected to electrical systems in
accordance with the wiring diagram (Fig.3). The thermostat
must be connected to a residual current disrupter with a max.
trigger current of 30mA.
The thermostat can withstand a load of max. 16A/3600W at
230V. At higher loads, the thermostat must control a contactor.
The thermostat does not have a galvanic insulation between
high current and low current. The sensor must therefore be
regarded as live (230V) and must be installed in accordance with
current requirements for high current installations.
The front cover is removed by pressing the locking clips into the
lower slot on each side of the thermostat (Fig.2). Take care not to
damage the thermostat.
Installation guide
Fig.1
Function indicators
Clock
Temperature
Selection buttons
OK-button
(changing functions)
On/off
MULTIREG
LCD2
01.01.2021
Version 2.28
Installation guide