PAGE 18 — GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05)
Figure 3D. 120/240V Full Power Switch
Simplified Diagram (Down Position)
Figure 3C. 120V Full Power Switch
Simplified Diagram (Up Position)
Figure 3B. Generator Components
GA-6RE/GA-6REA — CONTROLS AND INDICATORS
When the
full power switch
is in the
120V position, the 240V twist-lock
receptacle
cannot be used
.
NOTE
When the switch is in the 240 volt (down) position, you can
acess
half of the rated power
of the generating set at 120
volts from the GFCI duplex receptacle and up to half of the
rated power of the set at 120 volts from 120V twist-lock
receptacle; or full rated power of the set at 240 volts from
the 240V twist-lock receptacle.
13
. Full Power Switch –
The generators are provided with a
full power switch. Figures 3C and 3D show simplified wiring
diagrams of the dual voltage system.
When the full power switch is in the 120 volt (up) position,
you can access the
full rated power
of the generator at
120 volts from the GFCI duplex receptacle and the120V
twist-lock receptacle, or a combination of both receptacles
as long as the total load does not exceed the generating
set capacity.
Содержание GA-6RE
Страница 2: ...PAGE 2 GA 6RE GA 6REA A C GENERATORS OPERATION PARTS MANUAL REV 0 06 06 05...
Страница 37: ...GA 6RE GA 6REA A C GENERATORS OPERATION PARTS MANUAL REV 0 06 06 05 PAGE 37 NOTE PAGE...
Страница 75: ...GA 6RE GA 6REA A C GENERATORS OPERATION PARTS MANUAL REV 0 06 06 05 PAGE 75 NOTE PAGE...