background image

34 

Part Number: 9290312  October/22/2018

Maintenance 

Section 4

nteripr/Exteripr Cleaning, Sanitizing & Rinse

1.  Put on gloves and safety goggles before cleaning unit.
2.  Spray each tap with cleaner, wipe down, look for 

obstructions, and check for proper flow.

3.  Drain gate should be removed and interior of drain pan 

cleaned and wiped dry.

4.  Wash drain gate in sink and allow to dry.
5.  Spray top surface of unit with cleaner and wipe dry.
6.  Check interior for any spills or drips, spray with cleaner 

and wipe down.

DO NOT Spray 

Electronic 

Components!

Wipe down 

interior surfaces 

and any spills

,

Cautipn

Attention and care should be used to avoid spraying 

any electrical component (fans, thermostat and sensor 

connections) with any of the fluids.

Cpnnect Keg & PriIe SysteI 
Once all cleaning has been completed the keg can be 

reconnected to the system.

Imprtant

Make sure new coffee keg has been chilled to the 

operating temperature range of 45° - 36°F (7° - 2°C) 

before use or may cause foaming in the system.

• 

See “Keg Change” on page 21

•  Close cabinet door and unit is ready for use.

LEVEL 3 - MONTHLY CLEANNG
n Place Keg Cleaning

Perform the a weekly cleaning on all six (6) store kegs, three 

(3) product and three (3) cleaning. This can be performed 

during the weekly cleaning once a month. 

Содержание N2-Fusion ND21RS00

Страница 1: ...0312 October 22 2018 Nitrogen Beverage Dispensers Installation Operation Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Or...

Страница 2: ...icates a hazardous situation that if not avoided could result in death or serious injury Caution Indicates a hazardous situation that if not avoided could result in minor or moderate injury Notic Indi...

Страница 3: ...Electrical 8 Section 2 Installation Step by Step Installation 11 Pre installation Checklist 11 Remote Tower Installation 12 Nitrogen Regulator Tank Assembly 13 Nitrogen Installation Replacement 13 Ni...

Страница 4: ...ning Supplies 24 Manual Keg Cleaning 25 Level 1 Daily Cleaning 26 Level 2 Weekly Cleaning Single Step Method 29 Level 2 Weekly Cleaning Three Step Method 31 Level 3 Monthly Cleaning 34 Other Operation...

Страница 5: ...it when installing maintaining or servicing the unit nWarning Donotoperateequipmentthathasbeenmisused abused neglected damaged or altered modified from that of original manufactured specifications Thi...

Страница 6: ...S00 30 75 78 cm ND21RS02 This dimension represents units using 1 25 3 175 cm low profile casters regular casters are 1 25 3 175 cm taller nWarning To avoid instability the installation area must be ca...

Страница 7: ...ass 4 Location must have proper ventilation DO NOT install in an enclosure enclosed cabinet with no access to ambient air The location must not be near heat generating equipment or in direct sunlight...

Страница 8: ...ment start up when the electrical load is highest Check all green ground screws cables and wire connections to verify they are tight before start up Minimum Circuit Amperage Chart Importan Due to cont...

Страница 9: ...OTE For 220 240 VAC 50 60 Hz International Units a ground male plug must be supplied at the installation of the unit nWarning When using electric appliances basic precautions must always be followed i...

Страница 10: ...10 Part Number 9290312 October 22 2018 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 11: ...should be noted and reported to the delivering carrier immediately Check the lower portion of the unit to be sure casters are not bent Visually inspect the refrigeration package compressor compartmen...

Страница 12: ...and tower mount screw holes will be drilled 3 Cut and drill holes in the counter using the markings NOTE Drip trays equipped with a drain will need a 7 8 2 22 cm hole drilled into the counter using t...

Страница 13: ...death or injury when the cylinder valve is opened 2 ALWAYS follow correct procedures when cylinders are changed 3 ALWAYS secure the cylinder in an upright position with a chain 4 NEVER drop or throw a...

Страница 14: ...d always check the locking collars on the taps are tight prior to connecting the Nitrogen supply line If these collars are loose they can leak at the tower shank when pressurized Flow Control Locking...

Страница 15: ...si 2 psi 303 MPa 303 kPa 3 03 bar If adjustments are needed the installer or technician will need to remove the rear cover to access the regulators DANGER ELECTRICAL SHOCK HAZARD The power supply is l...

Страница 16: ...See Keg Change on page 21 Priming the System on page 20 5 The system is now ready to be primed 6 Press the Prime Clean button located in the upper left corner of the refrigeration cabinet once to pri...

Страница 17: ...LENOID VALVE TAP 1 PLAIN COFFEE TAP 2 NITRO COFFEE FILTER STRAINER PUMP N NITROGENATOR TANK NITROGENATED COFFEE OUT TO TAP 2 PLAIN CHILLED COFFEE TO NITROGENATOR PLAIN CHILLED COFFEE PLAIN CHILLED COF...

Страница 18: ...p hinge pin from door 4 Use a putty knife or similar tool to remove both plugs from door to expose alternate hinge pin locations and re install the plugs in original hinge pin locations 5 Install top...

Страница 19: ...ently of the compressor PRIME CLEAN BUTTON The Prime Clean button is located in the upper left corner of the refrigeration cabinet This button is used for priming the system with coffee cleaning and d...

Страница 20: ...g Importan If priming fails to complete the system will go into an error state and the Prime Clean button LED will blink continuously until the error is cleared NOTE If error occurs See Clearing Error...

Страница 21: ...S IN gray fitting from the keg by pulling up on the ring around the connector to release from the post Pull up on ring around connector to release 2 Leave the COFFEE OUT black fitting connected to the...

Страница 22: ...mit of the system of 100 psi 689 MPa 689 kPa 6 89 bar When valve relieves there may be a quick pressure relief sound heard coming from cabinet Relief sound shouldn t last more than a few seconds and m...

Страница 23: ...not damage the refrigeration circuit when installing maintaining or servicing the unit nWarning Never Use Steel Pads Wire Brushes or Scrapers Importan Never use a high pressure water jet for cleaning...

Страница 24: ...in resistant and easy to clean Products containing abrasives will damage the coating and scratch the panels Daily cleaning may be followed by an application of stainless steel cleaner which will elimi...

Страница 25: ...Duty Multi Purpose Sink Detergent from the dispenser at the back room sink or other approved cleaning solution mixed to the proper concentration with warm tap water in the keg 3 Use the urn brush to s...

Страница 26: ...efore wiping off TAP 1 Surface TAP 2 Importan TAP 2 Contains an o ring diffuser disc and diffuser 2 Spray each nozzle and allow to air soak for 15 minutes or as directed by manufacturer before wiping...

Страница 27: ...that may still be in the line or bowl during removal C Grasp the bowl and rotate counterclockwise to loosen and remove the bowl Strainer Gasket Bowl NOTE The strainer is a metal mesh ring that will be...

Страница 28: ...28 Part Number 9290312 October 22 2018 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 29: ...proper weekly cleaning See Manual Keg Cleaning on page 25 Level 3 Monthly Cleaning on page 34 Coffee Delivery System Cleaning Sanitizing 1 Disconnect coffee keg and set aside Clean In line Strainer 2...

Страница 30: ...cleaning process will need to start over from the beginning after a two 2 minute wait NOTE If an error is encountered at any time during cleaning process the cleaning button will blink ON OFF rapidly...

Страница 31: ...eg connectors cleaning solution keg 6 Press and release the Prime Clean button to prime the system with cleaning solution The LED around the button will flash ON then OFF Prime Clean Button Cleaning K...

Страница 32: ...button turns on to place the unit into cleaning mode NOTE Cleaning button will illuminate blue in color around the button indicating unit is in cleaning mode 7 Unit will automatically run through the...

Страница 33: ...t Step 1 and 2 for other keg connectors Keg Connector Sanitizing Frequency Every week or as required 1 Mix proper concentration of approved sanitizing solution in clean bucket and place keg connectors...

Страница 34: ...Components Wipe down interior surfaces and any spills Caution Attention and care should be used to avoid spraying any electrical component fans thermostat and sensor connections with any of the fluids...

Страница 35: ...pull out of the frame which may damage both the doors and the hinges In some cases this may require qualified service agents or maintenance personnel to perform repairs Door Adjustment If the door nee...

Страница 36: ...36 Part Number 9290312 October 22 2018 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 37: ...the thermometer reads below 50 F Refer to refrigeration section checklist See Controls Programming Settings on page 19 and Keg Change on page 21 Coffee keeps leaking from the clear drain hose The nit...

Страница 38: ...s are closed when not in use Avoid prolonged door openings Door gasket s not sealing properly Check gasket condition Adjust door or replace gasket if necessary Dirty condenser coil Clean the condense...

Страница 39: ...heck are 1 Verify connections to keg and if coffee keg is empty If keg is empty follow replacement steps on page 16 2 If keg has coffee check nitrogen level at nitrogen tank If outlet pressure drops b...

Страница 40: ...40 Part Number 9290312 October 22 2018 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...emier chain operators or growing independents with industry leading equipment and solutions Our cutting edge designs and lean manufacturing tactics are powered by deep knowledge operator insights and...

Отзывы: