background image

 

Page 1 of 62 

© 2021 Multidyne 

www.multidyne.com 

 

 

 
 
 

INSTRUCTION MANUAL 

 

FiberNet Routing Matrix 

Modular 3G/HD/SD-SDI Video Router 

 
 
 
 

 

 

 
 
 
 
 

 

 
 

Содержание FiberNet FN-64-CHAS

Страница 1: ...Page 1 of 62 2021 Multidyne www multidyne com INSTRUCTION MANUAL FiberNet Routing Matrix Modular 3G HD SD SDI Video Router...

Страница 2: ...ATUTORY OR OTHERWISE RELATED TO THE INFORMATION INCLUDING BUT NOT LIMITED TO ITS CONDITION QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Multidyne disclaims all liability arising from thi...

Страница 3: ...etwork Settings 12 1 5 3 Matrix Routing 12 1 5 4 Labels 12 1 5 5 Presets 12 1 6 Network Planning 12 1 6 1 Installation Example 14 2 Web page interface 14 2 1 Overview 14 2 2 Routing Tab 14 2 2 1 Chang...

Страница 4: ...DHCP Command 27 3 10 4 E Command 28 3 10 5 Firmware Command 28 3 10 6 FrameIP Command 29 3 10 7 Gateway Command 29 3 10 8 Get Command 29 3 10 9 GetS Command 30 3 10 10 Help Command 31 3 10 11 IP Comm...

Страница 5: ...S Command 45 3 10 38 SerBaud Command 45 3 10 39 Set Command 46 3 10 40 SetA Command 47 3 10 41 SetS Command 47 3 10 42 SrcNames Command 47 3 10 43 SysName Command 48 3 10 44 SysType Command 48 3 10 4...

Страница 6: ...Page 6 of 62 2021 Multidyne www multidyne com FN 64 CHAS Product Manual 6 2 Serial Interface Pinout 58 6 3 GPIO Auxiliary Interface 59 6 4 Glossary 61 7 MultidyneWarranty 62...

Страница 7: ...auto re clocked for reduced jitter Other non standard rates between 125 Mbit s and 2 97 Gbit s will be passed through without re clocking or jitter reduction Adaptive cable equalization on each input...

Страница 8: ...additional details General Purpose I O A D25 connector provides a GPIO auxiliary port with up to 24 input or output 3 3V logic lines for control and status interfacing with external equipment LEDs but...

Страница 9: ...is already mounted installation can still be performed but the I O boards will need to be inserted horizontally which makes finding the card connector by feel slightly more difficult 3 Ensuring the c...

Страница 10: ...is inserted into To remain cost effective it is thus recommended that transmit only or receive only SFP modules are used when planning system I O Model Description MDOPT00820 3G Video Transmitter SFP...

Страница 11: ...is made during purchase an example being a multi device application 1 5 1 Accessing The Web Page Interface The default network IP address for this device is 192 168 2 60 Device Type Default IPAddress...

Страница 12: ...bels can be up to 8 characters in length The default source labels use Src as a prefix and the destination labels use Dest as a prefix example Src1 The presets are labeled Startup for Preset 0 and Pre...

Страница 13: ...ces on the same LAN need to be assigned unique IP addresses in the same IP subnet Multidyne devices are configured by default to use IP addresses in the class C IP subnet 192 168 2 x When integrating...

Страница 14: ...nly the Config and Command tabs Numbered sections in Figure 25 1 System name can be assigned on the Config tab 2 System firmware series and version 3 Tab navigation 4 Preset load drop down selection 5...

Страница 15: ...ad preset drop down selector 4 in Figure 25 and selecting the desired preset which is then loaded and applied to the current routing matrix More information on Presets is contained in the following Pr...

Страница 16: ...non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets Tab interface allows for several useful scenario...

Страница 17: ...ing any configuration settings click the Save button All Network Settings changes require a Reboot of the device in order to take effect After clicking Save click the Reboot button to restart the devi...

Страница 18: ...1 destination to control individual destinations of a 16x4 Router 16 source 4 destination Another usage scenario would be to have 2 separate panels control different levels of a Video Audio Router Co...

Страница 19: ...gure 29 provides access to the MDCP protocol interface Commands are typed on the Command text entry line followed by pressing the Enter key to execute them The results will be displayed in the text ar...

Страница 20: ...bset of the basic ISIS Protocol command set and therefore some 3rd party equipment may work without modification using this protocol For information about other third party control system manufacturer...

Страница 21: ...connecting should display the command prompt character 3 3Serial Access FiberNet Routing Matrix router systems come equipped with a serial port which can be used as another means of sending MDCP comma...

Страница 22: ...n of commands is entered to indicate readiness to receive additional commands If an error occurs in response to a command an error will be displayed prior to the prompt with the following format E00 E...

Страница 23: ...nt types Argument Valid Range Meaning Boolean 0 1 T F True False Boolean true or false value Cmd String MDCP command Cond String Condition statement See PanelCond Command Dest 1 N Destination number N...

Страница 24: ...rated by periods representing a tree structure similar to file folders or directories Table 15 below describes the columns in the System Parameter Table Parameter Parameter identifier consisting of on...

Страница 25: ...CP protocol commands and consists of matrix routing I O label preset and other primary system commands Command Arguments Description DestNames Dest Lvl Label Destination I O names command E 0 1 Matrix...

Страница 26: ...sh rate SerBaud Number Query or assign serial baud rate SysName String System name Vars Query all system configuration variables WebPass String Assign web password 3 10 Miscellaneous Commands These ad...

Страница 27: ...empty strings to indicate that the label of the first level should be used Examples DestNames Dest1 AudDest1 Dest2 Dest3 Dest4 DestNames 1 Dest1 AudDest1 DestNames 1 2 AudDest1 DestNames 1 2 The first...

Страница 28: ...hanges to be echoed in the form of an X command Xd s l Where d is the destination number s is the source number and l is the optional level number This is useful for diagnostic purposes or automation...

Страница 29: ...o query and assign the remote Router IP FrameIP 192 168 2 60 FrameIP 192 168 2 61 3 10 7 Gateway Command NOTE Superseded by the net gateway System Parameter Query or assign the network Gateway IP addr...

Страница 30: ...DF FE net netmask 255 255 255 0 pnl cmdEn 1 pnl ip 0 0 0 0 sys arch Pyxis sys descr sys firmware Pyxis 1 1 7 sys name MultiDyne Router Get mtx mtx serial 1 mtx sync 0 Get net ip net ip 192 168 2 60 3...

Страница 31: ...of the system Ip IP Set IP address of the system Example querying and assigning the IP address IP 192 168 2 60 IP 192 168 2 61 3 10 12 LockStatus Command Routers only Query the video lock status and...

Страница 32: ...ign a destination mapping on a single level for Dest1 to physical Dest2 Examples MapDest 1 4 4 2 3 2 MapDest 1 1 4 4 MapDest 1 5 MapDest 1 6 2 The examples above are for a 2 level router The first exa...

Страница 33: ...ping for a single source The third example maps source 1 to physical source 5 on all levels The fourth example maps source 1 to physical source 6 on the second level only 3 10 16 MDCPVer Command NOTE...

Страница 34: ...Video lock status query support reclk 4 Reclocker disable support Example MtxCfg 8 8 3 4 8 0 The example above is simple output no arguments for a matrix with 2 levels the first has 8 destinations 8...

Страница 35: ...A video 3G HD video analog audio or AES digital audio respectively DEST_COUNT Count of destinations for the level SRC_COUNT Count of sources for the level FLAGS A space separated list of flag keywords...

Страница 36: ...Real world examples of I O grouping include dual channel 3D video and combining multiple audio channels 4 AES digital audio streams for example Command Description MtxGroup Query current I O grouping...

Страница 37: ...preset Example to recall preset 1 P 1 3 10 21 PAdd Command Routers only Preset add command Adds a connection to a preset This can be used to incrementally create a preset without changing the active...

Страница 38: ...tocol Version 3 0 Query and assign panel button GPIO command macros This system provides a means to easily implement custom functionality in response to a panel button press or GPIO auxiliary port con...

Страница 39: ...ommands for more details Command Description PanelCmdEn Query panel button GPIO command and conditions enable PanelCmd 0 1 Enable or disable panel button GPIO command and conditions 0 disable 1 enable...

Страница 40: ...button or GPIO pin will clear the condition two consecutive single or double quotes represents an empty string Examples PanelCond 1 P0 2 P1 67 P0 PanelCond 1 1 P0 PanelCond 68 P1 PanelCond 68 The fir...

Страница 41: ...n 1 The first command queries the current external panel interface setting 0 disabled The second command enables the external panel interface 3 10 28 PanelRate Command Protocol Version 2 1 For changin...

Страница 42: ...protocol The only available option is currently the case insensitive value MDCP however additional control protocols may be added in the future Value is stored and recalled on power up Command Descrip...

Страница 43: ...gh power cycles Command Description PSub PRESET DEST Remove any existing connection to DEST in PRESET for any level PSub PRESET DEST LEVEL Remove any existing connection to DEST LEVEL in PRESET Exampl...

Страница 44: ...for disabling or enabling SDI reclockers Not all router systems support this option Value is saved and recalled on power up Command Description ReclkDis Query current value of reclocker disable ReclkD...

Страница 45: ...quivalent to the X Command with no arguments If an argument value of 1 is supplied then the matrix state is displayed with labels The state of each destination is displayed one per line in the format...

Страница 46: ...r depends on the parameter and is defined in the System Parameter Table Values in Stored memory are loaded at system startup See System Parameters for more details Command Description Set List all par...

Страница 47: ...estarted NOTE Some parameters may not be assignable in Stored memory for example if it does not make sense to recall a value on start up See System Parameters for more details Command Description SetS...

Страница 48: ...Multidyne systems This value is stored and recalled on power up Command Description SysName Query system name SysName STR Set system name up to 15 characters Example for querying and assigning system...

Страница 49: ...iguration values Command Description Vars Display all system configuration parameters Note that variables consisting of JSON data simply show the string JSON to keep the output concise The output cons...

Страница 50: ...ing and clearing web page password WebPass SeCr3t WebPass 3 10 48 X Command Routers only Query or make changes to the matrix routing state This command comes in several variations described by the fol...

Страница 51: ...tion 3 only the third command connects source 4 to destination 3 on all levels and the fourth command mutes destination 4 level 2 Command stacking Command stacking is especially useful for the X comma...

Страница 52: ...o be displayed at which point the update image has been transferred to the device s FLASH storage area 5 The device will automatically reboot to perform the remainder of the software update during whi...

Страница 53: ...ection for details 4 3TFTP Software There are many different options for TFTP client programs the choice of which depends on what operating system you are using on the computer being used to perform t...

Страница 54: ...TFTP transfer Make sure to perform the necessary actions to prepare the system for an update prior to attempting the transfer 8 The TFTP program will indicate if the transfer was successful or not 9...

Страница 55: ...o replace MD Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer Make sure to perform the necessary actions to p...

Страница 56: ...le reset switch with a long paper clip while the device is running A computer system can then be configured with an IP address on the same IP subnet and the webpage configuration can be loaded for vie...

Страница 57: ...ata Types SMPTE 259 292 424 Data Rates 19 Mbit s through 3 0 Gbit s Re clocking Data Rates 270 Mbit s 1 485 Gbit s 2 97 Gbit s Input Output Return Loss 15dB HD 12dB 3G Input Level 800 mV P P 20 Input...

Страница 58: ...be used when connecting between a computer s RS 232 serial interface and the device This interface can be used up to 115 2 Kbits sec This device also comes equipped with an RS 485 serial interface wh...

Страница 59: ...pose I O auxiliary interface is provided on a female DB 25 connector and provides additional control and status functionality Pin Name 1 GP1 14 GP2 2 GP3 15 GP4 3 GP5 16 GP6 4 GP7 17 GP8 5 GP9 18 GP10...

Страница 60: ...Page 60 of 62 2021 Multidyne www multidyne com FN 64 CHAS Product Manual...

Страница 61: ...ased protocol for interfacing to Multidyne devices Matrix Used when referring to a Router s entire routing state Mute When supported a destination can be muted which for video means the output is turn...

Страница 62: ...istent with the warranty contained herein shall be of no force or effect 2 LIMITATIONS ON WARRANTY Products that are purchased from other equipment manufacturers and sold by MultiDyne Inc as part of a...

Отзывы: