SPECIFICATIONS

Infrared

Measurement Range (72-820)

-20

o

C-400

o

C (-4

o

F-752

o

F) 

Accuracy  

Ambient temperature  

21

o

C-25

o

C (70

o

F-77

o

F)

>0

o

C: ±2.0

o

C or ±2% of reading, whichever is greater 

<0°C: ±(2.0

o

C+0.1

o

C/

o

C) 

>32

o

F: ±4.0

o

F or ±2% of reading, whichever is 

greater

<32°F: ±(4.0

o

F+0.1

o

F/

o

F)

Temperature coefficient 

±0.1°C/°C or ±0.1%/°C, whichever is greater 

(±0.1°F/°F or ±0.1%/°F, whichever is greater)

Distance to Spot

10:1 (calculated at 90% energy)

Emissivity

0.95

Response Time

1.8% or (1.8

o

C/4

o

F)

Repeatability

0.5% of reading or 1

o

C/2

o

F

Response Time

<500ms (95% of reading)

Spectral response 

5.5um-14um

Resolution

0.1°C (0.1°F) 

Repeatability

1°C or 1.0%, whichever is greater 

 

(2°F or 1.0%, whichever is greater)

Laser

Single laser, wavelength 630nm-670nm  

Output power <1mW, class 2 laser

Power

Class 2 Output <1mV, wavelength 630 to 670mm

Power Supply

2 off AAA 1.5V Battery

Dimensions

135mm x 94mm x 36mm

Weight

148g (including batteries) 

Note:

 In the presence of a strong electromagnetic field, the product may result up to 

±10°C or 20% variation of the measured value. If this variation is observed, move the 

meter out from the field area for an accurate measurement.

Содержание MP780003

Страница 1: ...1 Model MP780003 Mini Infrared Thermometer...

Страница 2: ...rature changes allow 30 minutes for the Thermometer to stabilize before use Do not leave the Thermometer on or near objects of high temperature Please refer to the emissivity information for the actua...

Страница 3: ...last measurement data that was held before the last shutdown Temperature Measurement Aim the thermometer at the target then pull and hold the trigger The laser indicator on the LCD display shows that...

Страница 4: ...r is as shown in the figure below The spot diameter represents 90 of the energy in the circle The maximum D S 10 1 will be obtained when the thermometer is 400mm 16 from the target resulting in a spot...

Страница 5: ...setting Allow time for the tape or paint to reach the same temperatures as the surface beneath it Measure the temperature of the tape or painted surface MAINTENANCE Changing the battery To install or...

Страница 6: ...o C 4o F Repeatability 0 5 of reading or 1o C 2o F Response Time 500ms 95 of reading Spectral response 5 5um 14um Resolution 0 1 C 0 1 F Repeatability 1 C or 1 0 whichever is greater 2 F or 1 0 whiche...

Страница 7: ...ears on display when measuring The min or max ambient operating temperature has been exceeded Place the thermometer in a 0o C 50o C 32o F 122o F environment and it can be recovered after 30 mins Batte...

Страница 8: ...is required Do not dispose of these items with general household waste Separate for the treatment recovery and recycling of the materials used Waste batteries can be returned to any waste battery recy...

Отзывы: