Calibrate Sensor
The Calibrate Sensor function is used to calculate the Z-axis backlash with the Ohmic Sensor and should be run
occasionally to verify the correct relationship between the 2 components.
1. Press
Menu
to access the menu system.
2. Press
X-axis Jog Arrows
until Utility is highlighted in blue.
3. Press
Enter
to access the Utility sub-menu.
4. Press
X-axis Jog Arrows
until Calibrate Sensor is highlighted in blue.
5. Press
Enter
to access the Calibrate Sensor function.
6. Press
Jog Arrows
to position the head assembly over the material to be cut.
7. Press
Z-axis Jog Arrows
to lower the Z-axis until the end of the head assembly is approximately
1/4” above the material.
8. Press
Enter
to begin the calibration routine. The machine will move the Z head down until the Ohmic
Sensor senses the material, and the display will briefly show the calculated distance before automatically
returning to the Utility sub-menu.