3 AT Commands, Result Codes and S-Registers
Command:
&F
n
Load Factory Default Settings
Values:
n = 0
Default:
None
Description:
&F0
Load factory settings as active configuration.
Command:
&G
n
V.22bis Guard Tone Control
Values:
n = 0, 1, or 2
Default:
0
Description:
&G0
Disable guard tone.
&G1
Enable 550 Hz guard tone.
&G2
Enable 1800 Hz guard tone.
Note: The &G command is not used in North America.
Command:
&J
n
Auxiliary Relay Control
Values:
n = 0
Default:
0
Description:
&J0
The auxiliary relay is never closed.
&J1
Not supported—responds ERROR.
Command:
&K
n
Local Flow Control Selection
Values:
n = 0, 3, or 4
Defaults:
3
Description:
&K0
Flow control disabled.
&K3
Enable CTS/RTS hardware flow control.
&K4
Enable XON/XOFF software flow control.
Command:
&M
n
Communications Mode
Values:
n = 0
Defaults:
0
Description:
&M0
Asynchronous mode.
&M1
Reserved—responds ERROR.
Command:
&Q
n
Asynchronous Communications Mode
Values:
n = 0, 5, or 6
Defaults:
5
Description:
&Q0
Asynchronous with data buffering. Same as
\N0.
&Q5
Error control with data buffering. Same as
\N3.
&Q6
Asynchronous with data buffering. Same as
\N0.
Содержание MT5634ZPX
Страница 1: ......
Страница 6: ...vi...
Страница 7: ...Chapter 1 Introduction and Description...
Страница 14: ...MT5634ZPX 14 Owner s Manual...
Страница 15: ...Chapter 2 Installation...
Страница 44: ...MT5634ZPX 44 Owner s Manual...
Страница 45: ...Chapter 3 AT Commands Result Codes and S Registers...
Страница 64: ...MT5634ZPX 64 Owner s Manual...
Страница 65: ...Chapter 4 Troubleshooting...
Страница 74: ...MT5634ZPX 74 Owner s Manual...
Страница 75: ...Chapter 5 Warranty Service and Tech Support...
Страница 83: ...Appendices...
Страница 107: ...MT5634ZPX 107 Appendices...
Страница 108: ...MT5634ZPX 108 Owner s Manual...