Страница 1: ...2011 PATENTED 2011 SKYLINK GROUP Home Smart Center www skylinkhome com CUSTOMERSERVICE 17 Sheard Avenue Brampton Ontario Canada L6Y 1J3 Tel 905 456 8883 Fax 905 456 7819 Email support skylinkhome com MODEL ML 001 ML 100 TM ...

Страница 2: ...Home Smart Center USER S INSTRUCTIONS English ...

Страница 3: ...om lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord and batteries indicated in this manual Do not dispose of batteries in a fire They may explode Check with local codes for possible special disposal instructions 5 Plug the adaptor to the socket outlet that near the equipment and shall be easily accessible SAVE THESE INSTRUCTIONS Attent...

Страница 4: ...arly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electri cian as appropriate The Ringer Equivalence Number is an indication of the maximum number of terminals allowed to be connected to a telephone inter face The termination on an interface may consist of any combination of devices...

Страница 5: ...gger 45 Trouble Shooting 47 Accessories 49 System Configuration 53 FCC Information 53 CE 55 g Should you experience trouble with this equipment please contact Skylink Customer Support at 1 800 304 1187 for repair or warranty information If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved h Pleas...

Страница 6: ...approved terminal equipment c A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by theACTA Acompliant telephone cord and modular plug is provided with this product It is designed to be connected to a compatible modular jack that is also compliant See installation instructions for de...

Страница 7: ...1 For ML 100A Only Master Password ____________________ Secondary Password ____________________ Duress Password ____________________ ZONE SENSOR 1 SENSOR 2 BEEP ALARM AUTO MUTE EVENT TRIGGER ALERT Example Front Door Front Window Beep Alarm Y N Disabled On Off Y N 1 2 3 4 5 Sensor locations and settings Phone number settings PHONE MEMORY PHONE NUMBER REDIAL COUNT REPEAT COUNT Example 321 123 4567 5...

Страница 8: ...ages 6 16 17 7 11 8 1 2 4 18 13 12 Control Module SW 100 US and Canada To turn home appliances lights on off Max rating 960W Resistive Control Module SW 101U UK SW 101F French SW 101G German 3 models for 3 countries To turn home appliances lights on off Emergency Dialer AD 433S External dialer with user programmable voice message Calls up to 9 phone numbers One personal voice recording up to 40 se...

Страница 9: ...inside the battery compart ment The power adapter should be connected to an AC electrical outlet You should see all LEDs turn on LO BATT LED should be off Language selector ACCESSORIES Audio Sensor AS 101 When audio level exceeds preset limit it will trigger the alarm Place beside smoke detector CO detector so when these detectors are triggered the control panel will be triggered Remote Control 4B...

Страница 10: ... is intended to be mounted on a flat wall 2 screws are required to mount the control panel securely on the wall It should not be mounted too high or too low In most situations just below eye level is ideal 11 Once you have selected the mounting location tighten 2 screws on the wall They should be 7 1 8 apart from each other on the same horizontal level Do not tighten the screws all the way in leav...

Страница 11: ...te After mounting the door sensor it Please ensure the magnet is aligned with doesn t work anymore the red marking on the transmitter If you are mounting the sensor on to a metal door or window a spacer may be required to avoid magnetic interference caused by the metal door window Make sure the sensor is within the operation range of the control panel by bringing it closer to the control panel My ...

Страница 12: ...e number Enter phone memory 1 2 3 4 5 6 Step Keys Function Description Note Questions Solutions Why I can t arm my system Make sure none of the sensors are triggered You can check this by the zone LEDs none of them should blink I cannot arm the system even when no You need to disarm the system again by sensor is triggered and the ARM LED either entering the password or disarm by is off keychain re...

Страница 13: ...ogrammed phone doesn t ring ensure the phone number is programmed correctly or reprogram this phone number again 4 After the emergency message has been played for several times depending on how many times it was programmed the called party will hear Enter Password 5 Enter either the master password or secondary password If the correct password is accepted you will hear Password Accepted otherwise ...

Страница 14: ...ol panel will transmit a signal to activate the designated control module Applications include Lights on when you open the front door walking into a room lights on automatically this is called Event Trigger on Lights off when you open a door walk away from a room turns lights off this is called Event Triggered off Event trigger is only applicable to the sensor s and control module in the same zone...

Страница 15: ...ccount number is accepted You will hear Password Accepted Enter the new account num ber again for confirmation HOME AUTOMATION Part 2 Erase communication from Control Panel to Control Module ZONE LED DESCRIPTION Off Zone is not occupied by any control module Flashes twice That means a remote has occupied that zone THISISNOTACONTROLMODULE THEREFORE SHOULDNOTBE ERASED Flashes once That zone is occup...

Страница 16: ...will flash or stay off The zone LEDs represent whether that zone is occupied by any control module See Table F Select the control module location you would like to erase Refer to the table below to select the control module location After you have selected the remote location you will hear 3 beeps and verbal confirmation Device X Empty Memory where X is the control module location you have selecte...

Страница 17: ...move the battery isolator by pulling out the yellow tab Once the isolator is removed the corresponding zone LED on the control panel will flash and buzzer will beep If the magnetic contact is closed the beeping will stop Note Both Window Door Sensors have been programmed at the factory They are Zone 1 Sensor 1 and Zone 2 Sensor 1 Trigger the sensor and listen to the beeping and zone LED to determi...

Страница 18: ...red You will hear Device X Accepted where X is the control module location 4 Step Keys Function Description Note 16 41 Note Try to mount the sensors as far away from the floor as possible to avoid damaging them Mounting the sensors at a higher position will also result in better operating range Do not mount the sensor to the exterior of the door window always mount the sensor to the interior side ...

Страница 19: ... or furnace vents fans ovens space heaters etc Air movement especially caused by changes in temperature may trigger the Motion Sensor and cause false alarms Please carefully test your Motion Sensor so that it will only be triggered by wanted movement You have now successfully installed and programmed the Control Panel and its sensors Please follow the rest of the instructions for operations and ad...

Страница 20: ...g and LED flashing 1 Number of beeps Zone of the triggered sensor 2 Number of flashes of zone LED Sensor number of the triggered sensor Alert Mode 18 ADVANCED PROGRAMMING Zone 1 SENSOR 1 Button 1 SENSOR 2 Zone 2 Zone 3 Zone 4 Zone 5 Button 2 Button 3 Button 4 Button 5 Button 6 Button 7 Button 8 Button 9 Button 0 This row Buttons for Sensor 1 Zone LED Flash once This row Buttons for Sensor 2 Zone L...

Страница 21: ...should have this feature disabled Repeat this step for all 4 zone dependent features during programming 5 You may now follow the procedure below Learn Sensor Continue to program the sensor s to the desired zone s Learn Sensors Continue 1 2 3 4 PROG MPIN Enter Program ming mode Enter master password to programming mode 3 beeps for valid password 1 long beep for invalid password 3 Select learn senso...

Страница 22: ... a sensor you must decide which sensor location zone number and sensor number you would like to program the sensor to It is strongly recom mended that you refer to Sensor Location Selection Guide before deciding which sensor location you would like to program the new sensors to Some features you may need to consider are 1 Beep Alarm setting 2 auto mute 3 alert zone 4 event trigger Explanation for ...

Страница 23: ... panel before the siren sounds OPERATION 1 Entering the premises will trigger the entry delay 2 Enter password within 30 seconds or press the disarm button on the keychain remote 3 Once the system is disarmed the Arm LED will be off BeepBeep Entrydelay30seconds Arm LED off System Disarmed BeepBeep Arm LED flashes ADVANCED PROGRAMMING Erase Keychain Keypad Remotes 1 2 3 PROG MPIN Enter Programming ...

Страница 24: ...d password is entered you will hear System Disarmed and the entry delay beeping will stop the ARM LED will be off 22 35 ADVANCED PROGRAMMING ZONE LED DESCRIPTION Off Zone is not occupied by any remote Flashes twice This zone is occupied by another remote Programming another remote to this zone will overwrite the previous remote Flashes once This zone is occupied by a control module Optional You ca...

Страница 25: ...nditions the control panel will advise the user These trouble conditions include Phone Line Failure Sensor Failure loss of supervisory signal Low Battery Control Panel Low Battery Sensors Phone Line Failure When the phone line is disconnected or malfunctions the control panel will instantly notify the user by 1 Both Power PWR and Program PROG LEDs will flash together 2 Voice announcement Phone Lin...

Страница 26: ...e failed sensor is not physically damaged try to activate the sensor and see if the control panel reacts to such activation 3 If not try to remove the sensor from its location and bring it closer to control panel and activate the sensor It is possible that the sensor is installed too far from the control panel and it cannot establish a steady communication with the control panel If this is the cas...

Страница 27: ... not stop until the door is closed If the door is open for 2 hours the beep will go on for 2 hours There are times that this is not desired With the auto mute feature enabled the beep will go on for only 20 seconds After that even if the sensor remains open the beep will stop only the zone LED will flash to indicate the sensor is triggered Beep will go on again if the sensor is closed and opened a...

Страница 28: ...on of how to control the system remotely please refer to the next section Remote Operation by Telephone Zone1 Sensor 1 Triggered Enter Password Arm Disarm Check status Control lighting etc Disconnect COMMUNICATION 31 ADVANCED PROGRAMMING Follow the procedures below to program the beep alarm setting 1 2 PROG MPIN EnterProgramming mode Enter master password to programmingmode 3 beeps for valid passw...

Страница 29: ...n have access to all the operations listed below 30 System Armed Alarm Mode If a zone is set to Beep the control panel will give entry exit delay If a zone is set to Alarm the siren will sound immediately without entry delay Alarm Mode System Armed If a sensor is triggered i e opening a door with the alarm setting on the siren will sound immediately without entry delay it is called Instant Alarm T...

Страница 30: ...ontrol panel is armed or disarmed the audio warning is different System Disarmed Alert Mode If a zone is set to Beep the control panel will beep when a sensor is triggered until the sensor is deactivated Motion Sensor activation will not cause any beeping unless the zone for the motion sensor is programmed as a Bypass Zone see page 33 If a zone is set to Alarm alarm will sound instantly when a sen...