5
Pipe Installation
1
. Set the toilet in position against the wall.
The floor must be even and insulated.
2. Measure and make a hole for the ventilation
pipein the ceiling, 55 mm (2
1
/4'') diameter.
Install the ventilation pipe with the
non-sleeved end down inside the
coupling on the toilet.
3. Measure and make a hole in the roof,
with 55 mm (2
1
/4'') diameter.
4. Push the pipe up through the hole. Seal it
well using asphalt sealant between the pipe
and the roof to prevent any leaks.
5. lnsulate the pipe from the ceiling up to the top.
All pipework in cold spaces must be
insulated.
6. Cut the exterior pipe to fit the angle of the roof.
7. Push the roof flashing over to the exterior
pipe. (Use soap water to make it easier).
If you have a tin roof, get a sheet metal
worker to make a junction between the
roof and the exterior pipe.
8. Put the exterior pipe over the ventilation
pipe's insulation. Put the reduction
coupling on top.
9. Adjust the roof flashing and seal firmly with
asphalt sealant between the roof flashing and
the roof.
1
0. Fit the insect netting against the stop on the
reduction coupling.
Starting of toilet
1
. Put about 2/3 of the bag of the Biolet humusstarter into the toilet, except model 65ai where the whole
bag should be used. About half of the Humusstarter falls directly through the grate into the humus tray.
2. Connect the main plug into an grounded wall socket. Push the toilet seat down, the compostcover (20)
opens, which activates the mixer motor, The mixer-motor will automatically start and make one rotation,
repeat this a couple of times, in order to even out the humus starter.
The tray will be filled, and should stay this way until the compost chamber is filled to leveling arm (22a).
Restart after period of time off no use
1
. Mix the old compost in the chamber with the manual rake, add some water to make it moist, before
start using the toilet.
2. Add some humusstarter to the compost.
3. Connect the plug.
18° C /
Vent alt
25 mm (1
1
/
4
”) Insulation
Pipecover 110 mm (5”)
Reducing coupling
Netting
Roof flashing
25 mm (1
1
/
4
”)
Insulation
Ventilation pipe
Radiator
55mm (2
1
/
4
”)
Wall bracket
65° F
Nonsleeved end
Sleeved end
Roof flashing
seal of asphalt
Roof
Min. 1 meter
(4') above roof
Min. 0,5 meter
(2') above roof
Max
1,5
meter
(5')
Vent
alt.
EN