9
Virtual ECU application
Parameters
60
V5.20170221
31302713-02-EN
2.
Tap "Settings".
⇨
The existing virtual job computers appear.
⇨
If a job computer is activated, most of the other function icons are greyed-out.
3.
A maximum of five job computer profiles can be displayed on one page. To view other profiles,
swipe across the screen with your finger from bottom to top.
4.
To edit a job computer profile or to create a new one, you must deactivate the activated job
computer profile.
Parameters
Name
Name of the virtual job computer.
External Controller
If you have connected an on-board integrated display/controller or crop protection sensor to the serial
interface, you must select the model in this parameter.
The list contains the following devices:
▪ On-board integrated display/controllers that can communicate using one of the protocols ASD or
LH5000 and are capable of communicating with the terminal. If you want to connect an on-board
integrated display/controller that supports this protocol, but does not appear in the list, please
contact Müller-Elektronik.
▪ Crop protection sensors that can be connected to the serial interface of the terminal.
Implement type
Use this parameter to define the type of implement.
The following implement types are available:
▪ Planter/seeder
▪ Fertilizer spreader
▪ Sprayer
▪ Soil tillage
Swath width
This parameter shows the working width set for an ag equipment.
No. of sections
Enter the number of sections that can be switched off on the implement. On a field sprayer, they are
the section valves; on a fertilizer spreader or a planter/seeder, they can be e.g. metering units.
This parameter serves to transmit the proper number of sections to the SECTION-View module, so
that you can switch the sections manually.
Each section appears as part of the working bar on the screen.
9.2