Manually entering the number of impulses per liter for the flow meter
If you know the precise number of impulses per liter for the flow meter, you can enter this value
manually.
Please note that the number of impulses per litre must always be based on clear water.
1.
Switch to the “FLOW METER” screen:
>
>
2.
Enter number of impulses per litre on the “Impulses main flow” line.
Configuring products
You can configure all of the products that you work with in the product database.
To configure the products:
1.
Switch to the “Flow meter” screen:
>
>
⇨
The “Flow meter” screen appears.
2.
Select the product that you want to configure.
3.
Set the factor with which the “Impulses main flow” parameter should be multiplied for the
selected product. The “Impulses main flow” parameter must be correctly calibrated beforehand.
4.
- Set the product as the currently utilised product.
5.
- As an option, you can change the product name.
6.
You can also repeat the procedure for other products.
Selecting and configuring the speed sensor
You must enter the source from which the job computer shall obtain the current speed.
The configuration procedure can differ depending on the speed source.
Selecting the speed source
Supported speed sources:
▪
“Sensor” – Sensors that are installed on the implement and connected to the job computer:
– Examples: Wheel sensor, radar sensor, impulse-transmitting GPS speed sensor
– Configuration: Configure the number of impulses per 100 meters.
▪
“ISOBUS” – Sensors that are installed on the tractor and whose signal is received through the
ISOBUS.
– Examples: GPS receiver, wheel sensor on the tractor, signal socket
– Configuration: For systems without the option of selecting the sensor input, the “Wheel
impulses” parameter must be set to 0.