7.7 Fuel System
7.7.1 Fuel system – Venting
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Diesel fuel
WARNING
Fuels are combustible.
Risk of fire and explosion!
• Avoid open flames, electrical sparks and ignition sources.
• Do not smoke.
Venting LP fuel system
1.
Open vent plug (1).
2.
Unlock fuel priming pump (2), screw out
handle by turning it counterclockwise.
3.
Operate the pump with the handle (2) until
bubble-free fuel emerges from the vent
plug (1).
4.
Close vent plug (1).
5.
Screw in handle by turning it clockwise.
6.
Verify that fuel priming pump (2) is locked:
handle must be tightened.
152 | Task Description | M015710/04E 2012-09