Task Description
141
6.16.2
Charge-air coolant filling
Preconditions
• Engine is stopped and starting disabled.
• MTU Fluids and Lubricants Specification (A001061/..) is available.
Material
Designation / Use
Part No.
Qty.
Coolant
Spare parts
Designation / Use
Part No.
Qty.
Sealing ring
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
• Wear ear protectors.
CAUTION
Cold coolant in hot engine can cause thermal stress.
Formation of cracks in components!
• Fill / top up coolant only into cold engine.
Preparatory steps
1. Turn breather valve on coolant expansion tank
counterclockwise to first stop and allow pressure to
escape.
2. Continue to turn breather valve counterclockwise
and remove.
3. Remove plug screw from filling point on coolant
line to intercooler.
Charge-air coolant filling
1. Fill treated coolant through filling line or through filler neck of coolant expansion tank until coolant level
reaches marking plate.
2. Install plug screws of filling points with new sealing rings.
3. Check proper condition of breather valve and clean sealing faces, if required.
4. Set breather valve onto filler neck and close it.
Final steps
1. Start the engine and operate it at idle speed for some minutes.
2. Check coolant level (
MS15009/00E 06-09
© MTU
Содержание Detroit Diesel 12 V 2000 P62
Страница 18: ...14 Safety MS15009 00E 06 09 MTU...
Страница 62: ...58 Operation MS15009 00E 06 09 MTU...
Страница 136: ...132 Task Description Left side 1 Engine coolant drain plug 2 Engine coolant drain plug MS15009 00E 06 09 MTU...
Страница 137: ...Task Description 133 Right side 1 Engine oil drain plug heat exchanger 2 Engine coolant drain plug MS15009 00E 06 09 MTU...
Страница 188: ...184 Engine Governor Assignment and Circuitry MS15009 00E 06 09 MTU...
Страница 196: ...192 Special Tools Part No Designation Use Qty F30025897 Socket wrench 1 MS15009 00E 06 09 MTU...
Страница 198: ...194 Special Tools MS15009 00E 06 09 MTU...
Страница 199: ...Annex 195 9 Annex 9 1 Manufacturer s documentation See Manufacturer s documentation MS15009 00E 06 09 MTU...
Страница 204: ...200 Annex MS15009 00E 06 09 MTU...
Страница 208: ......