4.15 Stopping the engine from LOP
Preconditions
☑
Engine is running in local mode.
NOTICE
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
• Before shutting down, disengage gear and run the engine at idle speed for at least 10 minutes until
engine temperatures have dropped and constant values are displayed.
Stopping the engine from LOP
Item
Measure
LOP
Disengage gearbox (→ Page 72).
LOP
Operate engine at idle speed (→ Page 72).
Temperature indications
Wait until engine temperatures do not fall any further.
LOP
Press STOP illuminated pushbutton (→ Page 72).
• STOP button is illuminated.
• Engine at a standstill.