4.14 Waterjet – Flushing from LOP (optional)
Preconditions
☑
LOCAL OPERATION illuminated switch is lit brightly (local operating mode is active).
☑
Waterjet-BucketVessel at standstill and waterjet bucket is below the waterline.
☑
Engine speed is in engagement window.
☑
No external engagement interlock is active.
NOTICE
Waterjet flushing puts excessive strain on the bearings.
Bearing damage!
• Do not flush waterjet for too long.
• Follow instructions of the waterjet manufacturer.
Flushing with reversing gearbox and flushing mode
Item
Measure
LOP
Press and hold down FLUSH illuminated pushbutton (→ Page 69).
• FLUSH illuminated pushbutton flashes.
• Gearbox is engaged ASTERN.
• FLUSH illuminated pushbutton is brightly lit after receiving feedback sig-
nal from clutch.
LOP
Release FLUSH illuminated pushbutton.
• FLUSH illuminated pushbutton flashes.
• Gearbox is disengaged (neutral position).
• FLUSH illuminated pushbutton goes out after receiving feedback signal
from clutch.
84 | Operation | MS150046/03E 2018-08
TIM-ID: 0000002330 - 008
Содержание 20V4000M73 series
Страница 1: ...Operating Instructions Diesel engine 20V4000M73x MS150046 03E...
Страница 3: ......
Страница 4: ......