5.3 Engine – Starting in manual mode
Preconditions
☑
Engine is not under load.
☑
External start interlock is not activated.
DANGER
Rotating and moving engine parts.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Before cranking the engine with starter system, make sure that there are no persons in the engine's
danger zone.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
• Wear ear protectors.
Preparation
Item
Measure
Operating mode switch (if
applicable).
Switch to manual mode.
Coolant preheating unit (if
applicable).
Switch ON
Start engine
Item
Measure
Switchgear cabinet, opera-
tor station etc. (depending
on manufacturer).
1. If no coolant preheater is fitted, make sure that the coolant temperature
is > 40 °C.
2. Press start button.
• Automatic starting procedure is performed.
• Engine speed instrument indicates increasing speed.
• After the starting sequence is completed, engine is running at idle
speed.
MS150049/04E 2017-04
| Operation | 47
TIM-ID: 0000002233 - 006