7.18 Battery-Charging Generator
7.18.1 Battery-charging generator – Check
Preconditions
☑ Engine is stopped and starting disabled.
WARNING
Compressed air
Risk of injury!
• Do not direct compressed-air jet at persons.
• Wear protective goggles / safety mask and ear protectors.
Checking battery-charging generator
Item
Findings
Measure
Ventilation area (arrow)
Clean
None
Ventilation area (arrow)
Contaminated
Clean
Cleaning battery-charging generator
Note:
Dry-clean battery-charging generator only.
1.
Remove coarse dirt from battery-charging generator.
2.
Blow out ventilation area (arrow) with compressed air until all dust is cleared.
134 | Task Description | MS150054/02E 2012-02